Development of fast-response PPAC with strip-readout for heavy-ion beams
Reviewed by Pithpith:HVKUYYLOopen to challenge →
classification
nucl-ex
physics.ins-det
keywords
beamsachieveddetectionefficiencyheavy-ionpositionresolutionstrip-readout
read the original abstract
A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u $^{132}$Xe, 300 MeV/u $^{132}$Sn, and 300 MeV/u $^{48}$Ca beams. A detection efficiency beyond 99% for these beams is achieved even at an incident beam intensity of 0.7 billion particles per second. The best position resolution achieved is 235 um (FWHM).