Pith. sign in

REVIEW

Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2401.08679 v2 pith:JABIMQQF submitted 2024-01-11 physics.ins-det hep-exnucl-ex

classification physics.ins-dethep-exnucl-ex
keywords beamsenergyxenon-basedchargep-10statestragglingresolution
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams cannot attain charge state equilibrium in the IC gas. In this study, a xenon-based gas (Xe+CH4), exhibiting a sufficiently large charge state changing cross section, was used in the IC to reach charge state equilibrium. The responses of ICs with P-10 and the xenon-based gases were examined using 238U beams and cocktail radioactive isotope (RI) beams with Z=40-90 at the RI Beam Factory (RIBF). For 238U beams at 165-344 MeV/u, the P-10 gas IC yielded an energy resolution of 1.9-3.0% in full width at half maximum (FWHM), which proved inadequate for Z identification in the uranium region. In contrast, the xenon-based gas IC demonstrated a satisfactory energy resolution of 1.4-1.6%. When using cocktail RI beams, a Z resolution of 1.28 and 0.74 was achieved by the P-10 and the xenon-based gas ICs, respectively, for beams with Z=84-88 at 200 MeV/u. The contrast in Z resolutions between the P-10 and the xenon-based gas ICs was effectively elucidated by the energy loss straggling model, incorporating collisional straggling and straggling due to charge state changes in the IC gases. The xenon-based gas IC, with more than 3sigma Z separation across a broad Z range (Z=40-90), emerged as a practical solution for Z identification of heavy ion beams.

Discussion (0). Continue with ORCID to comment.

Pith tools