Pith. sign in

REVIEW

Fiber-optic multimode interference sensing: comprehensive characterization and its potential for strain-insensitive temperature sensing

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2204.11044 v1 pith:K5TFKHZX submitted 2022-04-23 physics.optics physics.app-ph

Fiber-optic multimode interference sensing: comprehensive characterization and its potential for strain-insensitive temperature sensing

classification physics.optics physics.app-ph
keywords temperaturesensitivitystrainresultsmultimodesensorcomprehensivefiber
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

A strain-insensitive temperature sensor based on multimode interference using standard multimode fibers (MMFs) is proposed according to the comprehensive study of the characteristics of the MMFs. The temperature and strain dependences on the core diameter, numerical aperture (NA), and the length of the MMF section in the single-mode--multimode--single-mode (SMS) fiber structure are investigated experimentally. The results indicate that the larger core diameter of the MMF leads to higher temperature sensitivity but lower strain sensitivity (absolute values); the higher NA does not influence the temperature sensitivity but results in higher absolute value of strain sensitivity; the longer MMF section brings lower temperature sensitivity but does not have an impact on strain sensitivity. These findings also contribute to the theoretical analysis of the length dependence in the SMS fiber sensors. Besides, the results of the characterization study show that the strain sensitivity is relatively low, which brings a possibility to develop a strain-insensitive temperature sensor. The proposed sensor is used for temperature sensing while the strain is constantly applied from 0 to 1100 $\mu\epsilon$ with steps of 100 $\mu\epsilon$. The measured results are consistent with the comprehensive study. The mean temperature sensitivity is 6.14 pm/$^{\circ}$C with a standard deviation of 0.39 pm/$^{\circ}$C, which proves that the proposed temperature sensor exhibits good stability and is insensitive to strain. We expect that these results will provide a profound guideline to fiber sensors based on multimode interference.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.