Pith. sign in

REVIEW 3 cited by

MD-Dose: A diffusion model based on the Mamba for radiation dose prediction

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2403.08479 v2 pith:N42Z23DK submitted 2024-03-13 eess.IV cs.CVphysics.med-ph

classification eess.IVcs.CVphysics.med-ph
keywords dosedistributionmapsmd-dosenoiseradiationdiffusionmamba
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Radiation therapy is crucial in cancer treatment. Experienced experts typically iteratively generate high-quality dose distribution maps, forming the basis for excellent radiation therapy plans. Therefore, automated prediction of dose distribution maps is significant in expediting the treatment process and providing a better starting point for developing radiation therapy plans. With the remarkable results of diffusion models in predicting high-frequency regions of dose distribution maps, dose prediction methods based on diffusion models have been extensively studied. However, existing methods mainly utilize CNNs or Transformers as denoising networks. CNNs lack the capture of global receptive fields, resulting in suboptimal prediction performance. Transformers excel in global modeling but face quadratic complexity with image size, resulting in significant computational overhead. To tackle these challenges, we introduce a novel diffusion model, MD-Dose, based on the Mamba architecture for predicting radiation therapy dose distribution in thoracic cancer patients. In the forward process, MD-Dose adds Gaussian noise to dose distribution maps to obtain pure noise images. In the backward process, MD-Dose utilizes a noise predictor based on the Mamba to predict the noise, ultimately outputting the dose distribution maps. Furthermore, We develop a Mamba encoder to extract structural information and integrate it into the noise predictor for localizing dose regions in the planning target volume (PTV) and organs at risk (OARs). Through extensive experiments on a dataset of 300 thoracic tumor patients, we showcase the superiority of MD-Dose in various metrics and time consumption.

Discussion (0). Sign in to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. VMU-Diff: A Coarse-to-fine Multi-source Data Fusion Framework for Precipitation Nowcasting

    cs.CV 2026-05 unverdicted novelty 7.0 of 10

    VMU-Diff improves precipitation nowcasting via coarse multi-source Vision Mamba fusion followed by residual conditional diffusion refinement.

  2. Hybrid Compact Least-Squares and Central Weighted Essentially Non-Oscillatory Schemes for Hyperbolic Conservation Laws on Structured Curvilinear Grids

    physics.flu-dyn 2025-08 reject novelty 4.0 of 10

    No verifiable result: the abstract and body address unrelated topics, so the claimed CLS-CWENO schemes appear without derivation, experiments, or benchmarks.

  3. A Survey of Mamba

    cs.LG 2024-08 unverdicted novelty 2.0 of 10

    The paper consolidates existing research on Mamba models, their architecture variants, adaptations to different data modalities, and applications across domains.

Pith tools