Pith. sign in

REVIEW 1 cited by

Simulated assessment of light transport through ischaemic skin flaps

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2204.07166 v1 pith:NDOMUHQT submitted 2022-04-14 physics.med-ph physics.app-phphysics.bio-phphysics.optics

classification physics.med-phphysics.app-phphysics.bio-phphysics.optics
keywords tissuelightflapsmodelopticalpoint-of-careskinwavelengths
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Currently, free flaps and pedicled flaps are assessed for reperfusion in post-operative care using colour, capillary refill, temperature, texture and Doppler signal (if available). While these techniques are effective, they are prone to error due to their qualitative nature. In this research, we explore using different wavelengths of light to quantify the response of ischaemic tissue. The assessment provides us with indicators that are key to our goal of developing a point-of-care diagnostics device, capable of observing reduced perfusion quantitatively. We set up a detailed optical model of the layers of the skin. The layers of the model are given appropriate optical properties of the tissue, with due consideration of melanin and haemoglobin concentrations. We simulate 24 models of healthy, perfused tissue and perfusion-deprived tissue to assess the responses when illuminated with visible and near-infrared wavelengths of light. In addition to detailed fluence maps of photon propagation, we propose a simple mathematical model to assess the differential propagation of photons in tissue; the optical reperfusion factor (ORF). Our results show clear advantages of using light at longer wavelengths (red, near-infrared) and the inferences drawn from the simulations hold significant clinical relevance. The simulated scenarios and results consolidate the belief of a multi-wavelength, point-of-care diagnostics device and inform its design for quantifying blood flow in transplanted tissue. The modelling approach is applicable beyond the current research, wherein other medical conditions that can be mathematically represented in the skin can be investigated. Through these, additional inferences and approaches to other point-of-care devices can be realised.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Pruning for Sparse Diffusion Models based on Gradient Flow

    cs.LG 2025-01 conditional novelty 3.0 of 10

    Progressive soft pruning with the GraSP gradient-flow criterion gives small FID improvements over one-shot pruning on DDPMs at 50% sparsity.

Pith tools