Pith. sign in

REVIEW

Statistical methods for characterizing transfusion-related changes in regional oxygenation using Near-infrared spectroscopy (NIRS) in preterm infants

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1801.08153 v2 pith:NFBM7KAL submitted 2018-01-24 stat.AP

Statistical methods for characterizing transfusion-related changes in regional oxygenation using Near-infrared spectroscopy (NIRS) in preterm infants

classification stat.AP
keywords nirsoxygenationinfantsmethodspretermmesentericrso2changes
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Near infrared spectroscopy (NIRS) is an imaging-based diagnostic tool that provides non-invasive and continuous evaluation of regional tissue oxygenation in real-time. In recent years, NIRS has show promise as a useful monitoring technology to help detect relative tissue ischemia that could lead to significant morbidity and mortality in preterm infants. However, some issues inherent in NIRS technology use on neonates, such as wide fluctuation in signals, signal dropout and low limit of detection of the device, pose challenges that may obscure reliable interpretation of the NIRS measurements using current methods of analysis. In this paper, we propose new statistical methods to analyse mesenteric rSO2 (regional oxygenation) produced by NIRS to evaluate oxygenation in intestinal tissues and investigate oxygenation response to red blood cell transfusion (RBC) in preterm infants. We present a mean area under the curve (MAUC) measure and a slope measure to capture the mean rSO2 level and temporal trajectory of rSO2, respectively. Estimation methods are developed for these measures and nonparametric testing procedures are proposed to detect RBC-related changes in mesenteric oxygenation in preterm infants. Through simulation studies, we show that the proposed methods demonstrate improved accuracy in characterizing the mean level and changing pattern of mesenteric rSO2 and also increased statistical power in detecting RBC-related changes, as compared with standard approaches. We apply our methods to a NIRS study in preterm infants receiving RBC transfusion from Emory Univerity to evaluate the pre- and post-transfusion mesenteric oxygenation in preterm infants.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.