Pith. sign in

REVIEW 1 cited by

X2CT-GAN: Reconstructing CT from Biplanar X-Rays with Generative Adversarial Networks

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1905.06902 v1 pith:O55ZZ7JU submitted 2019-05-16 eess.IV cs.CV

classification eess.IVcs.CV
keywords x-rayx-raysadversarialmachinegenerativegeneratorlossmethod
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Computed tomography (CT) can provide a 3D view of the patient's internal organs, facilitating disease diagnosis, but it incurs more radiation dose to a patient and a CT scanner is much more cost prohibitive than an X-ray machine too. Traditional CT reconstruction methods require hundreds of X-ray projections through a full rotational scan of the body, which cannot be performed on a typical X-ray machine. In this work, we propose to reconstruct CT from two orthogonal X-rays using the generative adversarial network (GAN) framework. A specially designed generator network is exploited to increase data dimension from 2D (X-rays) to 3D (CT), which is not addressed in previous research of GAN. A novel feature fusion method is proposed to combine information from two X-rays.The mean squared error (MSE) loss and adversarial loss are combined to train the generator, resulting in a high-quality CT volume both visually and quantitatively. Extensive experiments on a publicly available chest CT dataset demonstrate the effectiveness of the proposed method. It could be a nice enhancement of a low-cost X-ray machine to provide physicians a CT-like 3D volume in several niche applications.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Scout-Dose-TCM: Direct and Prospective Scout-Based Estimation of Personalized Organ Doses from Tube Current Modulated CT Exams

    physics.med-ph 2025-06 conditional novelty 6.0 of 10

    A scout-image deep learning model with DCT-based tube current modulation encoding estimates organ doses with 7% mean absolute error, outperforming Global and Organ CTDIvol baselines across six organs.

Pith tools