Pith. sign in

REVIEW 2 cited by

Restore-RWKV: Efficient and Effective Medical Image Restoration with RWKV

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2407.11087 v3 pith:PQKVLTME submitted 2024-07-14 eess.IV cs.CV

classification eess.IVcs.CV
keywords imagemedicalrestorationrestore-rwkvmodelattentiondependenciesrwkv
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Transformers have revolutionized medical image restoration, but the quadratic complexity still poses limitations for their application to high-resolution medical images. The recent advent of the Receptance Weighted Key Value (RWKV) model in the natural language processing field has attracted much attention due to its ability to process long sequences efficiently. To leverage its advanced design, we propose Restore-RWKV, the first RWKV-based model for medical image restoration. Since the original RWKV model is designed for 1D sequences, we make two necessary modifications for modeling spatial relations in 2D medical images. First, we present a recurrent WKV (Re-WKV) attention mechanism that captures global dependencies with linear computational complexity. Re-WKV incorporates bidirectional attention as basic for a global receptive field and recurrent attention to effectively model 2D dependencies from various scan directions. Second, we develop an omnidirectional token shift (Omni-Shift) layer that enhances local dependencies by shifting tokens from all directions and across a wide context range. These adaptations make the proposed Restore-RWKV an efficient and effective model for medical image restoration. Even a lightweight variant of Restore-RWKV, with only 1.16 million parameters, achieves comparable or even superior results compared to existing state-of-the-art (SOTA) methods. Extensive experiments demonstrate that the resulting Restore-RWKV achieves SOTA performance across a range of medical image restoration tasks, including PET image synthesis, CT image denoising, MRI image super-resolution, and all-in-one medical image restoration. Code is available at: https://github.com/Yaziwel/Restore-RWKV.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. UniFuse: A Unified All-in-One Framework for Multi-Modal Medical Image Fusion Under Diverse Degradations and Misalignments

    cs.CV 2025-06 conditional novelty 6.0 of 10

    UniFuse jointly performs restoration, registration, and fusion of degraded, misaligned multimodal medical images in a single deep network, reporting better fusion metrics than staged baselines.

  2. FEAT: Full-Dimensional Efficient Attention Transformer for Medical Video Generation

    cs.CV 2025-06 conditional novelty 6.0 of 10

    FEAT combines spatial, temporal, and channel attention in a diffusion transformer and reports improved medical video generation metrics with lower parameter counts than Endora.

Pith tools