Pith. sign in

REVIEW 1 cited by

MiniCLEAN Dark Matter Experiment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1711.02117 v1 pith:SE33GHZY submitted 2017-11-06 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords detectorcalibrationminicleanargondarkmatterresultstarget
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with 92 photomultiplier tubes placed in the cryogen temperature with 4-$\pi$ coverage of a 500 kg (150 kg) target (fiducial) mass. The detector design strategy emphasizes scalability to target masses of order 10 tons or more. The detector is designed also for a liquid neon target that allows for an independent verification of signal and background and a test of the expected dependence of the WIMP-nucleus interaction rate. For MiniCLEAN, PMT stability and calibration are essential. The \textit{In-situ} optical calibration will be able monitor the PMT stability and maintain the calibration. In MiniCLEAN, we use a Light-Emitting Diode(LED)- based light injection system to provide single photons for calibration, the calibration can be performed in near real-time, providing a continuous monitor at the condition of the detector. The intrinsic $^{39}$Ar beta emitter provides another way to calibrate the detector thanks to well defined properties and uniformly distributed inside the detector volume. The energy scale can be determined by fitting the energy spectrum of experimental $^{39}$Ar data. Moreover, the preliminary results from cold gas run shows the best measurement on triplet lifetime ($\sim$ 3.5 $\mu$ s). The results confirms the high purity of argon is attained by MiniCLEAN's purification system. The long triplet lifetime in gaseous argon can be exploit to obtain better performance of pulse shape discrimination (PSD) for future dark matter detector, also the low density of gaseous argon reduced the multi-scattering neutron backgrounds. On the other hand, by injecting $^{39}$Ar spike, the electronic recoil events due to $^{39}$Ar beta decay can be used to test the limit of PSD in liquid argon. The results will be informative for future multi-tonne LAr detector.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The Eos detector: a demonstrator of hybrid optical detection technology

    physics.ins-det 2026-07 conditional novelty 6.0 of 10

    Eos, a 4-ton hybrid optical detector at Berkeley, has been built and is taking calibration data to demonstrate simultaneous Cherenkov and scintillation detection for future neutrino detectors.

Pith tools