pith. sign in

arxiv: 1107.1616 · v2 · pith:TT262GN3new · submitted 2011-07-08 · ❄️ cond-mat.mes-hall · cond-mat.other

Electron Counting Capacitance Standard with an improved five-junction R-pump

classification ❄️ cond-mat.mes-hall cond-mat.other
keywords chargesingle-electroncapacitancecountingelectronfive-junctionpartsquantum
0
0 comments X
read the original abstract

The Electron Counting Capacitance Standard currently pursued at PTB aims to close the Quantum Metrological Triangle with a final precision of a few parts in 10^7. This paper reports the considerable progress recently achieved with a new generation of single-electron tunnelling devices. A five-junction R-pump was operated with a relative charge transfer error of five electrons in 10^7, and was used to successfully perform single-electron charging of a cryogenic capacitor. The preliminary result for the single-electron charge quantum has an uncertainty of less than two parts in 10^6 and is consistent with the value of the elementary charge.

This paper has not been read by Pith yet.

discussion (0)