REVIEW
First test of a CdMoO₄ scintillating bolometer for neutrinoless double beta decay experiments with mathrm{{}¹¹⁶Cd} and mathrm{{}¹⁰⁰Mo} nuclides
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
First test of a CdMoO₄ scintillating bolometer for neutrinoless double beta decay experiments with mathrm{{}¹¹⁶Cd} and mathrm{{}¹⁰⁰Mo} nuclides
read the original abstract
A large cylindrical cadmium molybdate crystal with natural isotopic abundance has been used to fabricate a scintillating bolometer. The measurement was performed above ground at milli-Kelvin temperature, with simultaneous readout of the heat and the scintillation light. The energy resolution as FWHM has achieved from 5 keV (at 238 keV) to 13 keV (at 2615 keV). We present the results of the $\alpha$ versus $\beta$/$\gamma$ events discrimination. The low internal trace contamination of the $\mathrm{CdMoO_4}$ crystal was evaluated as well. The detector performance with preliminary positive indications proves that cadmium molybdate crystal is a promising absorber for neutrinoless double beta decay scintillating bolometric experiments with $\mathrm{{}^{116}Cd}$ and $\mathrm{{}^{100}Mo}$ nuclides in the next-generation technique.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.