Pith. sign in

REVIEW 1 cited by

Probing low-mass WIMP candidates of dark matter with tetrafluoroethane superheated liquid detectors

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1905.04706 v2 pith:TWRBIEOB submitted 2019-05-12 hep-ph astro-ph.GA

classification hep-phastro-ph.GA
keywords detectormasswimpcircliquidprobingrecoilsrequires
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Probing low mass (sub-GeV -- few GeV) Weakly Interacting Massive Particle (WIMP) candidates of dark matter through WIMP-induced nuclear recoils in direct detection experiments requires use of detector materials consisting of low mass target nuclei and low threshold energy. Here we explore the potential of superheated liquid detectors (SLD) with a hydrogen containing liquid, namely, tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$) (b.p.~$-26.3^\circ\,$C), as the target material for probing low mass WIMPs. It is found that few-keV level recoil energy thresholds possible for bubble nucleation by WIMP-induced $^{12}$C and $^{19}$F recoils in C$_{2}$H$_{2}$F$_{4}$ SLDs operated at atmospheric pressure and gamma-ray insensitive temperatures of $T\, \lesssim\, 35^\circ\,$C have the potential to allow WIMPs in the few-GeV mass range to be probed at a WIMP-nucleon spin-independent cross section sensitivity levels (90% C.L.) better than $4.6\times 10^{-5}\,$pb at WIMP masses down to $\sim$ 4 GeV with a total exposure of $\sim$ 1000 kg.day, provided that the ``thermodynamic efficiency" $\eta_{\rm T}$ that determines the bubble nucleation thresholds for the recoiling nuclei in C$_{2}$H$_{2}$F$_{4}$ is $\sim$ 50% or higher. Sensitivity to sub-GeV WIMP masses generally requires the detector to be sensitive to the WIMP-induced $^1$H recoils, which in turn requires the detector to be operated at temperatures $T\gtrsim 50^\circ\,$C and $\eta_{\rm T}$ close to 100%. At such relatively high temperatures (at atmospheric pressure), however, the detector would be sensitive to background gamma rays.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Review of Dark Matter

    physics.gen-ph 2019-08 unverdicted novelty 1.0 of 10

    A brief review of dark matter candidates and experiments with no new results and several factual errors.

Pith tools