Pith. sign in

REVIEW 2 cited by

VascularPilot3D: Toward a 3D fully autonomous navigation for endovascular robotics

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2405.09375 v2 pith:U2HPF5TE submitted 2024-05-15 cs.RO

classification cs.RO
keywords vascularpilot3dendovascularnavigationautonomousfastfullyguidewiremodules
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

This research reports VascularPilot3D, the first 3D fully autonomous endovascular robot navigation system. As an exploration toward autonomous guidewire navigation, VascularPilot3D is developed as a complete navigation system based on intra-operative imaging systems (fluoroscopic X-ray in this study) and typical endovascular robots. VascularPilot3D adopts previously researched fast 3D-2D vessel registration algorithms and guidewire segmentation methods as its perception modules. We additionally propose three modules: a topology-constrained 2D-3D instrument end-point lifting method, a tree-based fast path planning algorithm, and a prior-free endovascular navigation strategy. VascularPilot3D is compatible with most mainstream endovascular robots. Ex-vivo experiments validate that VascularPilot3D achieves 100% success rate among 25 trials. It reduces the human surgeon's overall control loops by 18.38%. VascularPilot3D is promising for general clinical autonomous endovascular navigations.

Discussion (0). Sign in to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Real-Time Guidewire Tip Tracking Using a Siamese Network for Image-Guided Endovascular Procedures

    eess.IV 2025-06 conditional novelty 4.0 of 10

    A Siamese network with edge-enhanced attention tracks guidewire tips in DSA video at 57 FPS, with 0.421 mm mean error on three test sequences and 0.148-0.708 mm error on two robotic tasks.

  2. Real-Time 3D Guidewire Reconstruction from Intraoperative DSA Images for Robot-Assisted Endovascular Interventions

    cs.RO 2025-06 reject novelty 4.0 of 10

    A CTA-guided inverse projection framework for real-time 3D guidewire reconstruction from single-view DSA is proposed, but the depth formula and evaluation do not establish true 3D accuracy.

Pith tools