Pith. sign in

REVIEW

Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2305.12141 v1 pith:VPVRWEQH submitted 2023-05-20 quant-ph

classification quant-ph
keywords fieldmagneticstatescw-odmrdressedfrequencymethodsensing
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution, even at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetic field sensing using continuous-wave opticallydetected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF) dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with a RF field at two different frequencies. One creates the RF dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on a RF field with a single frequency. The estimated bandwidth is 7.45 MHz, higher than that of the conventional method using the RF dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.

Discussion (0). Continue with ORCID to comment.

Pith tools