Pith. sign in

REVIEW 1 cited by

DDMM-Synth: A Denoising Diffusion Model for Cross-modal Medical Image Synthesis with Sparse-view Measurement Embedding

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2303.15770 v1 pith:WC6OYCUW submitted 2023-03-28 eess.IV cs.CVphysics.med-ph

classification eess.IVcs.CVphysics.med-ph
keywords modelddmm-synthdenoisingdiffusionmeasurementsmedicalsparse-viewcases
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Reducing the radiation dose in computed tomography (CT) is important to mitigate radiation-induced risks. One option is to employ a well-trained model to compensate for incomplete information and map sparse-view measurements to the CT reconstruction. However, reconstruction from sparsely sampled measurements is insufficient to uniquely characterize an object in CT, and a learned prior model may be inadequate for unencountered cases. Medical modal translation from magnetic resonance imaging (MRI) to CT is an alternative but may introduce incorrect information into the synthesized CT images in addition to the fact that there exists no explicit transformation describing their relationship. To address these issues, we propose a novel framework called the denoising diffusion model for medical image synthesis (DDMM-Synth) to close the performance gaps described above. This framework combines an MRI-guided diffusion model with a new CT measurement embedding reverse sampling scheme. Specifically, the null-space content of the one-step denoising result is refined by the MRI-guided data distribution prior, and its range-space component derived from an explicit operator matrix and the sparse-view CT measurements is directly integrated into the inference stage. DDMM-Synth can adjust the projection number of CT a posteriori for a particular clinical application and its modified version can even improve the results significantly for noisy cases. Our results show that DDMM-Synth outperforms other state-of-the-art supervised-learning-based baselines under fair experimental conditions.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. ReCoSeg++:Extended Residual-Guided Cross-Modal Diffusion for Brain Tumor Segmentation

    eess.IV 2025-08 reject novelty 4.0 of 10

    ReCoSeg++ extends ReCoSeg to BraTS 2021, feeding diffusion-derived T1ce residual maps to a 2D U-Net and reporting 93.02 Dice and 86.7 IoU for whole-tumor segmentation.

Pith tools