REVIEW 4 major objections 4 minor 43 references
Multipurpose in situ cell design for 3D X-ray imaging of electrochemical processes
T0 review · 4 major / 4 minor · reviewed 2026-08-07 · deepseek-v4-flash
Pith's one-line read A modular electrochemical cell enables real-time 3D X-ray imaging of corrosion and hydrogen embrittlement in metal microcrystals.
desk verdict A useful modular in situ cell for operando X-ray imaging, with real multi-beamline demonstrations; the electrochemical control claim outruns the reported data. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing object is the three-electrode flow cell itself: a glass-filled resin body printed by stereolithography, a reference electrode housed in a separate sealed port away from the working and counter electrodes, a sample stage with an embedded working-electrode wire, a Kapton film window for X-ray transmission, and interchangeable base adapters that mount the cell to different beamline hexapod stages. The updated design replaces fragile platinum wire contacts with conductive threaded screws and a stainless steel shim counter electrode, while keeping the sample surface just 50 micrometers above the cell horizon so the beam is never occluded.
What would settle it
Immerse coupons of the cell-body resin in 0.1 M HCl, pH-10 NaOH, and simulated PWR coolant for more than 30 hours and measure mass change, electrical conductivity, and electrolyte composition; any dissolution, swelling, or ion leaching would break the inertness claim. A second check: run the Cu hydrogen-charging experiment with no applied potential; if the lattice still expands, the observed signal is not electrochemical charging.
Extended reading notes
Core claim
The central claim is that a single modular, chemically inert electrochemical cell can be built with a decoupled reference electrode and used for operando synchrotron X-ray studies of material degradation. The paper demonstrates this in situ with both Bragg Coherent Diffraction Imaging and box-beam reflection-mode Dark Field X-ray Microscopy, showing real-time corrosion of Ni microcrystals in simulated PWR coolant and hydrogen charging of Cu microcrystals in HCl. The BCDI data reveal lattice-parameter expansion during hydrogen charging and the appearance of phase singularities and hollow cores consistent with dislocation formation during corrosion.
Load-bearing premise
The load-bearing premise is that the glass-filled resin forming the cell body is chemically inert and electrically insulating in the target electrolytes, a claim taken from the manufacturer's datasheet rather than verified in this paper.
Editorial extensions
If this is right
- If the cell is as inert and stable as claimed, researchers can run multi-day corrosion experiments at a beamline without cell-induced electrochemical background or X-ray artifacts.
- The decoupled reference electrode enables potentiostatic control such as the applied -1.0 V versus SHE used for hydrogen charging, so hydrogen embrittlement can be followed in real time with lattice parameter as the readout.
- Because only the base adapter is beamline-specific, the same cell body can be moved among different synchrotron stations with minimal redesign effort.
- Compatibility with both BCDI and DFXM means single-crystal strain evolution and broader grain or domain mapping can be captured on the same sample environment.
- The updated screw-based electrode contacts and conductive stage lower fabrication cost and remove fragile platinum wire handling, making replication for other groups easier.
Reading between the lines
- The same flow cell could plausibly be paired with an irradiation source to tackle coupled irradiation-corrosion questions in operando, which the paper motivates as a motivation but does not demonstrate.
- The observed homogeneous lattice expansion during Cu hydrogen charging could be developed into a quantitative hydrogen-concentration proxy if calibrated against known hydrogen-vacancy trapping energetics.
- Because the cell's inertness rests on manufacturer datasheet values, an immediate next step would be an in situ impedance or leaching measurement; the over-30-hour corrosion run is partial evidence but not a proof.
- The high measured flow rate suggests the design could also serve experiments where gas evolution or reaction products must be swept away quickly, such as high-rate hydrogen evolution studies, though this is a testable extension rather than a paper claim.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper describes the design, fabrication, and beamline deployment of a modular 3D-printed electrochemical flow cell for operando synchrotron X-ray imaging, with emphasis on Bragg Coherent Diffraction Imaging (BCDI) and Dark Field X-ray Microscopy (DFXM). The cell separates the reference electrode from the working and counter electrodes, uses a glass-filled SLA resin body, and is mounted on beamline-specific base adapters. Two BCDI experiments are presented as demonstrations: corrosion of Ni microcrystals in simulated PWR coolant at the P10 beamline, which shows Bragg peak splitting and phase singularities attributed to defect formation, and hydrogen charging of Cu microcrystals in 0.1 M HCl at the ID01 beamline, which shows lattice parameter expansion attributed to hydrogen incorporation. An updated design with a conductive thumbscrew stage and stainless steel counter electrode is also introduced. The paper concludes that the cell supports real-time corrosion and hydrogen embrittlement measurements under BCDI and DFXM configurations.
Significance. If the stated capabilities are established, the cell would be a useful, low-cost, modular sample environment for operando studies of material degradation at multiple synchrotron beamlines. Strengths of the paper include its open data availability, deployment at several beamlines, and clear presentation of the design evolution. However, the most expansive claims — precise electrochemical control and successful in situ use with DFXM — are not fully supported by the evidence reported. The corrosion demonstration was performed without any electrode connections or applied potential, and the hydrogen-charging demonstration lacks the electrochemical measurements needed to confirm the claimed applied potential at the sample surface. The DFXM claim is not accompanied by any DFXM data or analysis. These issues are load-bearing because they concern the central scientific claims of the abstract and introduction, but they are correctable by tempering the claims or adding the missing measurements.
major comments (4)
- [Introduction; X-ray Measurements; Results and Discussion] The paper claims that the cell 'has been successfully utilized in situ with both BCDI and box beam reflection-mode DFXM' and that the design supports measurements 'under both BCDI and DFXM configurations,' yet no DFXM data, image, or analysis appears anywhere in the Results. Figure 2 shows base adapters for several beamlines, but this only demonstrates mechanical compatibility, not successful DFXM operation. This claim should either be supported with a representative DFXM dataset or removed from the abstract and introduction.
- [Ni Corrosion in PWR Chemistry] In this experiment the flow cell 'was used without the reference electrode, and the entrance holes for the working and counter electrodes were sealed with epoxy.' No potential was applied or measured, so the run is an open-circuit immersion test, not a demonstration of the 'precise electrochemical control' claimed in the abstract. The abstract and introduction should be qualified so that the corrosion demonstration is described as open-circuit exposure, with the electrochemical-control capability supported only by the hydrogen-charging run, if at all.
- [Hydrogen Charging of Cu in HCl] The text states that an Ag/AgCl reference electrode 'was used to maintain a stable charging potential of -1.0 V vs SHE,' but no applied current, measured open-circuit potential, or iR-compensation information is reported. Because the reference electrode is housed in a side port connected through a narrow, unstirred path to the working electrode region, uncompensated solution resistance could make the true potential at the Cu microcrystal surfaces deviate substantially from -1.0 V vs SHE. The paper should report chronoamperometric or potential-step data, or at minimum explicitly state that the quoted potential is an uncorrected set-point value rather than a measured electrode potential.
- [In Situ Cell Design; Ni Corrosion in PWR Chemistry] The chemical inertness of the Rigid 10K resin is asserted on the basis of manufacturer datasheet values cited as [27], with the paper's own verification limited to 30 hours of exposure to the PWR coolant simulant. The claim that the cell withstands 'sustained exposure to highly acidic and basic environments, including hydrochloric acid and sodium hydroxide with a pH of 10' is therefore not substantiated by in-house testing. Either provide compatibility data for the specific electrolytes used in the target experiments or soften the claim to specify that only the tested environments have been validated in this work.
minor comments (4)
- [Design Advancements] The phrase 'which have been redesigned to contain leaks' is ambiguous and likely should read 'to contain the electrolyte' or 'to prevent leaks'; please clarify the intended meaning.
- [Hydrogen Charging of Cu in HCl] The text includes the typo 'demonstrate is suitability for electrochemical hydrogen charging' and should read 'demonstrate its suitability.'
- [Hydrogen Charging of Cu in HCl] The role of the Pt wire inserted through the working electrode channel is unclear: the cell design earlier describes a working electrode wire in contact with the sample, but here the sample is Cu on glassy carbon. Please clarify whether the Pt wire contacts the Cu particles directly, contacts the glassy carbon substrate, or serves only as a current lead.
- [In Situ Cell Design] The paper states that the cell is compatible with 'multiple 3D printing platforms' but only demonstrates fabrication on a Form 3+ printer; if other platforms have not been tested, this should be stated as a design intent rather than a demonstrated capability.
Circularity Check
No circularity: the paper is an experimental hardware report whose claims rest on direct beamline measurements, not on fitted inputs or self-referential derivations.
full rationale
This manuscript is a design-and-demonstration report for an electrochemical in situ cell. It does not derive a physical result from an assumed model; instead, it presents measurements acquired at synchrotron beamlines (BCDI and DFXM) and interprets them with standard phase-retrieval and strain-analysis tools. The central claims—that the cell supports real-time corrosion and hydrogen-charging measurements—are supported by direct observations such as evolving Bragg peaks, phase spirals, and lattice-parameter expansion. No equation in the paper is constructed so that an output equals an input by definition. The few self-citations (e.g., refs. [28] and [31]) appear only as references for sample preparation, prior beamline use, and analysis software; they are not invoked as the proof of any claim in this paper. The use of manufacturer datasheet values for the resin's resistivity and chemical resistance is an assumption about material properties, but it is not a circularity: the paper does not claim to derive those properties from its own measurements, and the in situ corrosion run over 30 hours provides independent, external evidence of stability in one relevant environment. Concerns about the electrochemical control achieved in a specific run (e.g., the PWR run without a reference electrode) are experimental-validity questions, not circularity. Therefore, no circular step exists, and the appropriate score is 0.
Assumptions & free parameters
assumptions (3)
- domain assumption The cell resin (Formlabs Rigid 10K) has the chemical resistance and electrical insulating properties stated in the manufacturer datasheet.
- domain assumption Kapton film windows are sufficiently transparent and non-scattering for the X-ray energies used (10.3 and 19.9 keV).
- domain assumption Solid-state dewetted microcrystals behave as isolated single crystals suitable for BCDI analysis.
Cite this review
Pith. "Pith review of Multipurpose in situ cell design for 3D X-ray imaging of electrochemical processes." pith.science (2026). https://pith.science/paper/WO2UDH2P
@misc{pith2026250604543,
author = {Pith},
title = {Pith review of: Multipurpose in situ cell design for 3D X-ray imaging of electrochemical processes},
year = {2026},
howpublished = {\url{https://pith.science/paper/WO2UDH2P}},
note = {Machine review of arXiv:2506.04543}
}
read the original abstract
We present the design of a modular multipurpose cell for monitoring the degradation of materials in extreme environments. This cell decouples the reference electrode from the working and counter electrodes, permitting precise electrochemical control and measurement reliability. The design is compatible with 4th generation synchrotron light sources, and its emphasis on modularity facilitates adaptation to different beamlines, where there may be variations in sample stage requirements and X-ray imaging techniques. Experimental tests with the novel design demonstrate its support of real-time corrosion and hydrogen embrittlement measurements under both Bragg Coherent Diffraction Imaging (BCDI) and Dark Field X-ray Microscopy (DFXM) configurations.
Figures
Figures from the paper (2 more)
Reference graph
Works this paper leans on
- [27]
-
[1]
1 - An overview of the corrosion chemistry
Saman Zehra, Mohammad Mobin, and Jeenat Aslam. “1 - An overview of the corrosion chemistry”. In: Environmentally Sustainable Corrosion Inhibitors . Ed. by Chaudhery Mustansar Hussain, Chandrabhan Verma, and Jeenat Aslam. Elsevier, 2022. DOI: https://doi.org/10.1016/ B978-0-323-85405-4.00012-4
work page 2022
-
[2]
W. H. J. Vernon. “THE CORROSION OF METALS”. In: Journal of the Royal Society of Arts 97.4798 (1949)
work page 1949
-
[3]
Chapter 5 - Electrochemical corrosion
R.A. Buchanan and E.E. Stansbury. “Chapter 5 - Electrochemical corrosion”. In: Handbook of Environmental Degradation of Materials. Ed. by Myer Kutz. Norwich, NY: William Andrew Publishing, 2005. DOI: https://doi.org/10.1016/B978-081551500-5.50007-0
-
[4]
Barbara Shaw and Robert Kelly. “What is Corrosion?” In: The Electrochemical Society Interface 15.1 (2006). DOI: 10.1149/2.F06061IF
-
[5]
Corrosion and Stress Corrosion Cracking Fundamentals
Gary S. Was. “Corrosion and Stress Corrosion Cracking Fundamentals”. In: Fundamentals of Radiation Materials Science: Metals and Alloys. New York, NY: Springer New York, 2017.DOI: 10.1007/978-1-4939-3438-6_15
-
[6]
2 - Overview of nuclear materials and nuclear corrosion science and engineering
D. F´eron. “2 - Overview of nuclear materials and nuclear corrosion science and engineering”. In:Nu- clear Corrosion Science and Engineering. Ed. by Damien F´eron. Woodhead Publishing Series in En- ergy. Woodhead Publishing, 2012. DOI: https://doi.org/10.1533/9780857095343. 1.31
-
[7]
Burnable Poisons in Nuclear Fuels
K.W. Hesketh. “Burnable Poisons in Nuclear Fuels”. In: Encyclopedia of Materials: Science and Technology. Ed. by K.H. J ¨urgen Buschow et al. Oxford: Elsevier, 2002. DOI: https://doi. org/10.1016/B0-08-043152-6/01835-0
Show all 43 references
-
[8]
Materials challenges in nuclear energy
S.J. Zinkle and G.S. Was. “Materials challenges in nuclear energy”. In:Acta Materialia 61.3 (2013). The Diamond Jubilee Issue. DOI: https://doi.org/10.1016/j.actamat.2012.11. 004
2013 doi
-
[9]
Hydrogen Embrittlement in Nuclear Power Systems
George Young, Edward Richey, and David Morton. “Hydrogen Embrittlement in Nuclear Power Systems”. In: 2012. DOI: 10.1533/9780857093899.1.149
2012 doi
-
[10]
A review of irradiation assisted stress corrosion cracking
P. Scott. “A review of irradiation assisted stress corrosion cracking”. In: Journal of Nuclear Materials 211.2 (1994). DOI: https://doi.org/10.1016/0022-3115(94)90360-3
1994 doi
-
[11]
Irradiation assisted corrosion and stress corrosion cracking (IAC/IASCC) in nuclear reactor systems and components
Gary Was and Peter Andresen. “Irradiation assisted corrosion and stress corrosion cracking (IAC/IASCC) in nuclear reactor systems and components”. In: Nuclear Corrosion Science and Engineering (2012). DOI: 10.1533/9780857095343.2.131
2012 doi
-
[12]
Environmentally Assisted Cracking of Irradiated Metals and Alloys
“Environmentally Assisted Cracking of Irradiated Metals and Alloys”. In: Fundamentals of Radia- tion Materials Science: Metals and Alloys. Berlin, Heidelberg: Springer Berlin Heidelberg, 2007. DOI: 10.1007/978-3-540-49472-0_15 . 8/10
2007 doi
-
[13]
The design, setup and operational testing of the irradiation and corrosion experiment (ICE)
P. Hosemann et al. “The design, setup and operational testing of the irradiation and corrosion experiment (ICE)”. In: Journal of Nuclear Materials 376.3 (2008). Heavy Liquid Metal Cooled Reactors and Related Technologies. DOI: https : / / doi . org / 10 . 1016 / j . jnucmat . ...
2008
-
[14]
Continuous Monitoring of Pure Fe Corrosion in Lead-Bismuth Eutectic Under Irradiation with Proton-Induced X-ray Emission Spectroscopy
Franziska Schmidt et al. “Continuous Monitoring of Pure Fe Corrosion in Lead-Bismuth Eutectic Under Irradiation with Proton-Induced X-ray Emission Spectroscopy”. In: JOM 73.12 (2021). DOI: 10.1007/s11837-021-04954-x
2021 doi
-
[15]
Accelerated corrosion and oxide dissolution in 316L stainless steel irradiated in situ in high temperature water
Stephen S. Raiman and Gary S. Was. “Accelerated corrosion and oxide dissolution in 316L stainless steel irradiated in situ in high temperature water”. In: Journal of Nuclear Materials 493 (2017). DOI: https://doi.org/10.1016/j.jnucmat.2017.05.043
2017 doi
-
[16]
Radiolysis driven changes to oxide stability during irradiation-corrosion of 316L stainless steel in high temperature water
Stephen S. Raiman, David M. Bartels, and Gary S. Was. “Radiolysis driven changes to oxide stability during irradiation-corrosion of 316L stainless steel in high temperature water”. In: Journal of Nuclear Materials 493 (2017). DOI: https://doi.org/10.1016/j.jnucmat.2017. 05.042
2017 doi
-
[17]
An X-ray photo-electron spectroscopic study on the role of molybdenum in increasing the corrosion resistance of ferritic stainless steels in HC1
K. Hashimoto, K. Asami, and K. Teramoto. “An X-ray photo-electron spectroscopic study on the role of molybdenum in increasing the corrosion resistance of ferritic stainless steels in HC1”. In: Corrosion Science 19.1 (1979). DOI: https://doi.org/10.1016/0010-938X(79) 90003-9
1979 doi
-
[18]
The mechanism of corrosion inhibition by chro- mate conversion coatings from x-ray absorption near edge spectroscopy (Xanes)
M.W. Kendig, A.J. Davenport, and H.S. Isaacs. “The mechanism of corrosion inhibition by chro- mate conversion coatings from x-ray absorption near edge spectroscopy (Xanes)”. In: Corrosion Science 34.1 (1993). DOI: https://doi.org/10.1016/0010-938X(93)90257-H
1993 doi
-
[19]
Operando methods: A new era of electrochemistry
Yao Yang et al. “Operando methods: A new era of electrochemistry”. In: Current Opinion in Electrochemistry 42 (2023). DOI: https : / / doi . org / 10 . 1016 / j . coelec . 2023 . 101403
2023
-
[20]
Developments in X-ray tomography characterization for electro- chemical devices
Thomas M.M. Heenan et al. “Developments in X-ray tomography characterization for electro- chemical devices”. In: Materials Today 31 (2019). DOI: https://doi.org/10.1016/j. mattod.2019.05.019
2019 doi
-
[21]
Coherent X-Ray Diffraction Imaging
Jianwei Miao, Richard L. Sandberg, and Changyong Song. “Coherent X-Ray Diffraction Imaging”. In: IEEE Journal of Selected Topics in Quantum Electronics18.1 (2012). DOI: 10.1109/JSTQE. 2011.2157306
2012
-
[22]
Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis
Rafael A. Vicente et al. “Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis”. In: ACS Nano 15.4 (2021). DOI: 10.1021/acsnano.1c01080
2021 doi
-
[23]
Dark-field X-ray microscopy for multiscale structural characterization
H. Simons et al. “Dark-field X-ray microscopy for multiscale structural characterization”. In: Nature Communications 6.1 (2015). DOI: 10.1038/ncomms7098
2015 doi
-
[24]
The ESRF dark-field x-ray microscope at ID06
M Kutsal et al. “The ESRF dark-field x-ray microscope at ID06”. In: IOP Conference Series: Materials Science and Engineering 580.1 (2019). DOI: 10 . 1088 / 1757 - 899x / 580 / 1 / 012007
2019
-
[25]
Direct Imaging of Hydrogen-Driven Dislocation and Strain Field Evolution in a Stainless Steel Grain
David Yang et al. Direct Imaging of Hydrogen-Driven Dislocation and Strain Field Evolution in a Stainless Steel Grain. 2025
2025
-
[26]
Formlabs Inc. Form 3+. 2025. URL: https://formlabs.com/store/3d-printers/ form-3-basic-package-without-service/#/ (visited on 06/03/2025)
2025
-
[28]
X-Ray Irradiation Induced Strain Relaxation of Dewetted Ni Particles on Modified Si Substrate
David Simonne et al. “X-Ray Irradiation Induced Strain Relaxation of Dewetted Ni Particles on Modified Si Substrate”. In: (2025). DOI: 10.2139/ssrn.5248343
2025 doi
-
[29]
Towards a quantitative determination of strain in Bragg Coherent X-ray Diffraction Imaging: artefacts and sign convention in reconstructions
J´erˆome Carnis et al. “Towards a quantitative determination of strain in Bragg Coherent X-ray Diffraction Imaging: artefacts and sign convention in reconstructions”. In: Scientific Reports 9.1 (2019). DOI: 10.1038/s41598-019-53774-2
2019 doi
-
[30]
Cdiutils: A python package for X-ray Bragg Coherent Diffraction Imaging pro- cessing, analysis and visualisation workflows
Clement Atlan. Cdiutils: A python package for X-ray Bragg Coherent Diffraction Imaging pro- cessing, analysis and visualisation workflows. Version v.0.1.4-beta. DOI: 10.5281/zenodo. 7656853. 9/10
-
[31]
Gwaihir: Jupyter Notebook graphical user interface for Bragg coherent diffraction imaging
David Simonne et al. “ Gwaihir: Jupyter Notebook graphical user interface for Bragg coherent diffraction imaging”. In: Journal of Applied Crystallography 55.4 (2022). DOI: 10 . 1107 / S1600576722005854
2022
-
[32]
PyNX: high-performance computing toolkit for coherent X-ray imaging based on operators
Vincent Favre-Nicolin et al. “ PyNX: high-performance computing toolkit for coherent X-ray imaging based on operators”. In: Journal of Applied Crystallography53.5 (2020). DOI: 10.1107/ S1600576720010985
2020
-
[33]
Reconstruction of an object from the modulus of its Fourier transform
J. R. Fienup. “Reconstruction of an object from the modulus of its Fourier transform”. In: Opt. Lett. 3.1 (1978). DOI: 10.1364/OL.3.000027
1978 doi
-
[34]
Relaxed averaged alternating reflections for diffraction imaging
D Russell Luke. “Relaxed averaged alternating reflections for diffraction imaging”. In: Inverse Problems 21.1 (2004). DOI: 10.1088/0266-5611/21/1/004
2004 doi
-
[35]
A practical algorithm for the determination of plane from image and diffraction pictures
Ralph W Gerchberg. “A practical algorithm for the determination of plane from image and diffraction pictures”. In: Optik 35.2 (1972)
1972
-
[36]
Equivalent of the point spread function for partially coherent imaging
Shalin B. Mehta and Colin J. R. Sheppard. “Equivalent of the point spread function for partially coherent imaging”. In: Optica 2.8 (2015). DOI: 10.1364/OPTICA.2.000736
2015 doi
-
[37]
Free log-likelihood as an unbiased metric for coherent diffraction imaging
Vincent Favre-Nicolin, Steven Leake, and Yuriy Chushkin. “Free log-likelihood as an unbiased metric for coherent diffraction imaging”. In: Scientific Reports 10.1 (2020). DOI: 10.1038/ s41598-020-57561-2
2020
-
[38]
ParaView: An End-User Tool for Large Data Visualiza- tion
J. Ahrens, Berk Geveci, and Charles Law. “ParaView: An End-User Tool for Large Data Visualiza- tion”. In: Visualization Handbook (2005)
2005
-
[39]
Three-dimensional imaging of dislocation propagation during crystal growth and dissolution
Jesse N. Clark et al. “Three-dimensional imaging of dislocation propagation during crystal growth and dissolution”. In: Nature Materials 14.8 (2015). DOI: 10.1038/nmat4320
2015 doi
-
[40]
Dissolving, trapping and detrapping mechanisms of hydrogen in bcc and fcc transition metals
Yu-Wei You et al. “Dissolving, trapping and detrapping mechanisms of hydrogen in bcc and fcc transition metals”. In: AIP Advances 3.1 (2013). DOI: 10.1063/1.4789547
2013 doi
-
[41]
Hydrogen-Enhanced Vacancy Diffusion in Metals
Jun-Ping Du et al. “Hydrogen-Enhanced Vacancy Diffusion in Metals”. In:The Journal of Physical Chemistry Letters 11.17 (2020). PMID: 32786653. DOI: 10.1021/acs.jpclett.0c01798
2020 doi
-
[42]
Thermodynamic analysis of the interaction between metal vacancies and hydrogen in bulk Cu
Vasileios Fotopoulos, Ricardo Grau-Crespo, and Alexander L Shluger. “Thermodynamic analysis of the interaction between metal vacancies and hydrogen in bulk Cu”. In: Physical Chemistry Chemical Physics 25.13 (2023)
2023
-
[43]
Defects Induced in Copper by Cathodic Charging of Hydrogen
S. Nakahara and Y . Okinaka. “Defects Induced in Copper by Cathodic Charging of Hydrogen”. In: Journal of The Electrochemical Society 136.7 (1989). DOI: 10.1149/1.2097074. 10/10
1989 doi
Reviewed August 7, 2026 · model on record in the stance chip above.