Pith. sign in

REVIEW 4 major objections 4 minor 43 references

Multipurpose in situ cell design for 3D X-ray imaging of electrochemical processes

T0 review · 4 major / 4 minor · reviewed 2026-08-07 · deepseek-v4-flash

Pith's one-line read A modular electrochemical cell enables real-time 3D X-ray imaging of corrosion and hydrogen embrittlement in metal microcrystals.

desk verdict A useful modular in situ cell for operando X-ray imaging, with real multi-beamline demonstrations; the electrochemical control claim outruns the reported data. read the letter →

arxiv 2506.04543 v1 pith:WO2UDH2P submitted 2025-06-05 physics.ins-det cond-mat.mtrl-sci

classification physics.ins-detcond-mat.mtrl-sci
keywords electrochemicalcelloperandoX-rayimagingBraggcoherentdiffractiondark-fieldmicroscopycorrosionhydrogenembrittlementsynchrotroninstrumentationthree-electrode
verification ladder T0 review T1 audit T2 compute T3 formal

The pith

A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.

The reading

The paper presents a reusable, modular electrochemical cell that lets synchrotron X-ray experiments watch corrosion and hydrogen embrittlement happen in real time. The cell separates the reference electrode from the working and counter electrodes, is built from a resin claimed to be chemically inert and electrically insulating, and uses interchangeable base adapters to fit different beamlines. Experimental runs show Ni microcrystals corroding in simulated PWR coolant while Bragg coherent diffraction imaging resolves evolving dislocations, and Cu microcrystals expanding as hydrogen is charged into their lattice. A sympathetic reader would take the core claim to be that one cell design can serve multiple operando X-ray imaging techniques and multiple degradation chemistries without contaminating the measurement.

What carries the argument

The load-bearing object is the three-electrode flow cell itself: a glass-filled resin body printed by stereolithography, a reference electrode housed in a separate sealed port away from the working and counter electrodes, a sample stage with an embedded working-electrode wire, a Kapton film window for X-ray transmission, and interchangeable base adapters that mount the cell to different beamline hexapod stages. The updated design replaces fragile platinum wire contacts with conductive threaded screws and a stainless steel shim counter electrode, while keeping the sample surface just 50 micrometers above the cell horizon so the beam is never occluded.

What would settle it

Immerse coupons of the cell-body resin in 0.1 M HCl, pH-10 NaOH, and simulated PWR coolant for more than 30 hours and measure mass change, electrical conductivity, and electrolyte composition; any dissolution, swelling, or ion leaching would break the inertness claim. A second check: run the Cu hydrogen-charging experiment with no applied potential; if the lattice still expands, the observed signal is not electrochemical charging.

Watch

Extended reading notes

Core claim

The central claim is that a single modular, chemically inert electrochemical cell can be built with a decoupled reference electrode and used for operando synchrotron X-ray studies of material degradation. The paper demonstrates this in situ with both Bragg Coherent Diffraction Imaging and box-beam reflection-mode Dark Field X-ray Microscopy, showing real-time corrosion of Ni microcrystals in simulated PWR coolant and hydrogen charging of Cu microcrystals in HCl. The BCDI data reveal lattice-parameter expansion during hydrogen charging and the appearance of phase singularities and hollow cores consistent with dislocation formation during corrosion.

Load-bearing premise

The load-bearing premise is that the glass-filled resin forming the cell body is chemically inert and electrically insulating in the target electrolytes, a claim taken from the manufacturer's datasheet rather than verified in this paper.

Editorial extensions

If this is right

  • If the cell is as inert and stable as claimed, researchers can run multi-day corrosion experiments at a beamline without cell-induced electrochemical background or X-ray artifacts.
  • The decoupled reference electrode enables potentiostatic control such as the applied -1.0 V versus SHE used for hydrogen charging, so hydrogen embrittlement can be followed in real time with lattice parameter as the readout.
  • Because only the base adapter is beamline-specific, the same cell body can be moved among different synchrotron stations with minimal redesign effort.
  • Compatibility with both BCDI and DFXM means single-crystal strain evolution and broader grain or domain mapping can be captured on the same sample environment.
  • The updated screw-based electrode contacts and conductive stage lower fabrication cost and remove fragile platinum wire handling, making replication for other groups easier.

Reading between the lines

Editorial extensions of the paper, not claims the author makes directly.

  • The same flow cell could plausibly be paired with an irradiation source to tackle coupled irradiation-corrosion questions in operando, which the paper motivates as a motivation but does not demonstrate.
  • The observed homogeneous lattice expansion during Cu hydrogen charging could be developed into a quantitative hydrogen-concentration proxy if calibrated against known hydrogen-vacancy trapping energetics.
  • Because the cell's inertness rests on manufacturer datasheet values, an immediate next step would be an in situ impedance or leaching measurement; the over-30-hour corrosion run is partial evidence but not a proof.
  • The high measured flow rate suggests the design could also serve experiments where gas evolution or reaction products must be swept away quickly, such as high-rate hydrogen evolution studies, though this is a testable extension rather than a paper claim.
Share X Bluesky LinkedIn Reddit HN

Editorial analysis

A structured set of objections, weighed in public.

Desk editor's note, referee report, and a circularity audit.

Referee Report

4 major / 4 minor

Summary. The paper describes the design, fabrication, and beamline deployment of a modular 3D-printed electrochemical flow cell for operando synchrotron X-ray imaging, with emphasis on Bragg Coherent Diffraction Imaging (BCDI) and Dark Field X-ray Microscopy (DFXM). The cell separates the reference electrode from the working and counter electrodes, uses a glass-filled SLA resin body, and is mounted on beamline-specific base adapters. Two BCDI experiments are presented as demonstrations: corrosion of Ni microcrystals in simulated PWR coolant at the P10 beamline, which shows Bragg peak splitting and phase singularities attributed to defect formation, and hydrogen charging of Cu microcrystals in 0.1 M HCl at the ID01 beamline, which shows lattice parameter expansion attributed to hydrogen incorporation. An updated design with a conductive thumbscrew stage and stainless steel counter electrode is also introduced. The paper concludes that the cell supports real-time corrosion and hydrogen embrittlement measurements under BCDI and DFXM configurations.

Significance. If the stated capabilities are established, the cell would be a useful, low-cost, modular sample environment for operando studies of material degradation at multiple synchrotron beamlines. Strengths of the paper include its open data availability, deployment at several beamlines, and clear presentation of the design evolution. However, the most expansive claims — precise electrochemical control and successful in situ use with DFXM — are not fully supported by the evidence reported. The corrosion demonstration was performed without any electrode connections or applied potential, and the hydrogen-charging demonstration lacks the electrochemical measurements needed to confirm the claimed applied potential at the sample surface. The DFXM claim is not accompanied by any DFXM data or analysis. These issues are load-bearing because they concern the central scientific claims of the abstract and introduction, but they are correctable by tempering the claims or adding the missing measurements.

major comments (4)
  1. [Introduction; X-ray Measurements; Results and Discussion] The paper claims that the cell 'has been successfully utilized in situ with both BCDI and box beam reflection-mode DFXM' and that the design supports measurements 'under both BCDI and DFXM configurations,' yet no DFXM data, image, or analysis appears anywhere in the Results. Figure 2 shows base adapters for several beamlines, but this only demonstrates mechanical compatibility, not successful DFXM operation. This claim should either be supported with a representative DFXM dataset or removed from the abstract and introduction.
  2. [Ni Corrosion in PWR Chemistry] In this experiment the flow cell 'was used without the reference electrode, and the entrance holes for the working and counter electrodes were sealed with epoxy.' No potential was applied or measured, so the run is an open-circuit immersion test, not a demonstration of the 'precise electrochemical control' claimed in the abstract. The abstract and introduction should be qualified so that the corrosion demonstration is described as open-circuit exposure, with the electrochemical-control capability supported only by the hydrogen-charging run, if at all.
  3. [Hydrogen Charging of Cu in HCl] The text states that an Ag/AgCl reference electrode 'was used to maintain a stable charging potential of -1.0 V vs SHE,' but no applied current, measured open-circuit potential, or iR-compensation information is reported. Because the reference electrode is housed in a side port connected through a narrow, unstirred path to the working electrode region, uncompensated solution resistance could make the true potential at the Cu microcrystal surfaces deviate substantially from -1.0 V vs SHE. The paper should report chronoamperometric or potential-step data, or at minimum explicitly state that the quoted potential is an uncorrected set-point value rather than a measured electrode potential.
  4. [In Situ Cell Design; Ni Corrosion in PWR Chemistry] The chemical inertness of the Rigid 10K resin is asserted on the basis of manufacturer datasheet values cited as [27], with the paper's own verification limited to 30 hours of exposure to the PWR coolant simulant. The claim that the cell withstands 'sustained exposure to highly acidic and basic environments, including hydrochloric acid and sodium hydroxide with a pH of 10' is therefore not substantiated by in-house testing. Either provide compatibility data for the specific electrolytes used in the target experiments or soften the claim to specify that only the tested environments have been validated in this work.
minor comments (4)
  1. [Design Advancements] The phrase 'which have been redesigned to contain leaks' is ambiguous and likely should read 'to contain the electrolyte' or 'to prevent leaks'; please clarify the intended meaning.
  2. [Hydrogen Charging of Cu in HCl] The text includes the typo 'demonstrate is suitability for electrochemical hydrogen charging' and should read 'demonstrate its suitability.'
  3. [Hydrogen Charging of Cu in HCl] The role of the Pt wire inserted through the working electrode channel is unclear: the cell design earlier describes a working electrode wire in contact with the sample, but here the sample is Cu on glassy carbon. Please clarify whether the Pt wire contacts the Cu particles directly, contacts the glassy carbon substrate, or serves only as a current lead.
  4. [In Situ Cell Design] The paper states that the cell is compatible with 'multiple 3D printing platforms' but only demonstrates fabrication on a Form 3+ printer; if other platforms have not been tested, this should be stated as a design intent rather than a demonstrated capability.

Circularity Check

0 steps flagged · score 0.0 of 10

No circularity: the paper is an experimental hardware report whose claims rest on direct beamline measurements, not on fitted inputs or self-referential derivations.

full rationale

This manuscript is a design-and-demonstration report for an electrochemical in situ cell. It does not derive a physical result from an assumed model; instead, it presents measurements acquired at synchrotron beamlines (BCDI and DFXM) and interprets them with standard phase-retrieval and strain-analysis tools. The central claims—that the cell supports real-time corrosion and hydrogen-charging measurements—are supported by direct observations such as evolving Bragg peaks, phase spirals, and lattice-parameter expansion. No equation in the paper is constructed so that an output equals an input by definition. The few self-citations (e.g., refs. [28] and [31]) appear only as references for sample preparation, prior beamline use, and analysis software; they are not invoked as the proof of any claim in this paper. The use of manufacturer datasheet values for the resin's resistivity and chemical resistance is an assumption about material properties, but it is not a circularity: the paper does not claim to derive those properties from its own measurements, and the in situ corrosion run over 30 hours provides independent, external evidence of stability in one relevant environment. Concerns about the electrochemical control achieved in a specific run (e.g., the PWR run without a reference electrode) are experimental-validity questions, not circularity. Therefore, no circular step exists, and the appropriate score is 0.

Assumptions & free parameters 0 free parameters · 3 assumptions · 0 invented entities

No free parameters are fitted; the paper is an experimental instrument report. The assumptions listed are the load-bearing premises about material behavior and X-ray transparency that the central claims rely on.

assumptions (3)
  • domain assumption The cell resin (Formlabs Rigid 10K) has the chemical resistance and electrical insulating properties stated in the manufacturer datasheet.
    Central to the claim that the cell is chemically inert and does not influence electrochemistry; cited in the 'IN SITU CELL DESIGN' section with reference [27].
  • domain assumption Kapton film windows are sufficiently transparent and non-scattering for the X-ray energies used (10.3 and 19.9 keV).
    No quantitative transmission data are given; the measured Bragg peaks must be attributable to the sample, not the window.
  • domain assumption Solid-state dewetted microcrystals behave as isolated single crystals suitable for BCDI analysis.
    The phase retrieval treats each particle as an isolated crystal; this follows the established preparation process cited from reference [28].

how reviews work

0 comments
Cite this review

Pith. "Pith review of Multipurpose in situ cell design for 3D X-ray imaging of electrochemical processes." pith.science (2026). https://pith.science/paper/WO2UDH2P

@misc{pith2026250604543,
  author       = {Pith},
  title        = {Pith review of: Multipurpose in situ cell design for 3D X-ray imaging of electrochemical processes},
  year         = {2026},
  howpublished = {\url{https://pith.science/paper/WO2UDH2P}},
  note         = {Machine review of arXiv:2506.04543}
}
read the original abstract

We present the design of a modular multipurpose cell for monitoring the degradation of materials in extreme environments. This cell decouples the reference electrode from the working and counter electrodes, permitting precise electrochemical control and measurement reliability. The design is compatible with 4th generation synchrotron light sources, and its emphasis on modularity facilitates adaptation to different beamlines, where there may be variations in sample stage requirements and X-ray imaging techniques. Experimental tests with the novel design demonstrate its support of real-time corrosion and hydrogen embrittlement measurements under both Bragg Coherent Diffraction Imaging (BCDI) and Dark Field X-ray Microscopy (DFXM) configurations.

Figures

Figures reproduced from arXiv: 2506.04543 by the authors.

Figure 1
Figure 1. (A) Render of the cell with components indicated. (B) Image of the cell in use at the ID01 nanodiffraction beamline (ESRF) during operando embrittlement. (C) Render of the sample environment with the cell lid and Kapton film removed. The front half of the cell was made transparent and the modeled sample was cut in half to show the internals. The outline of the sample contact surface is shown over the sample stage. (… view at source ↗
Figure 2
Figure 2. Drawings of the base adapters with dimensions shown in mm. The base adapters differ primarily in the placement of screw holes for affixing the cell to the beamline-dependent hexapod stage. Each base design is labeled with its respective beamline. The beamlines are ID03 (ESRF), P10 (DESY), ID01 (ESRF), and SixS (SOLEIL), respectively. X-RAY MEASUREMENTS X-ray experiments were carried out at the ID01 and ID03 beamline… view at source ↗
Figure 3
Figure 3. [PITH_FULL_IMAGE:figures/full_fig_p005_3.png] view at source ↗
Figures from the paper (2 more)
Figure 4
Figure 4. Figure 4: Charging of Cu microcrystals on glassy carbon reveals ensemble changes in lattice parameter. (A) An XZ slice of the (111) Bragg peak is shown for each particle. (B) Each particle’s Bragg peak is used to calculate the homogeneous lattice parameter (Error bars represent …
Figure 5
Figure 5. Figure 5: (A) A cross-sectional view of the updated design with modified and additional components labeled. (B) An overview of the same design mounted on an updated, backwards compatible version of the ID01 base adapter. The original design of the cell has enabled real-time moni…

Discussion (0). Sign in to comment.

Reference graph

Works this paper leans on

43 extracted references · 36 canonical work pages

  1. [27]

    Rigid 10K Resin

    Formlabs. Rigid 10K Resin. Technical Data Sheet. Formlabs, Inc. 2020

  2. [1]

    1 - An overview of the corrosion chemistry

    Saman Zehra, Mohammad Mobin, and Jeenat Aslam. “1 - An overview of the corrosion chemistry”. In: Environmentally Sustainable Corrosion Inhibitors . Ed. by Chaudhery Mustansar Hussain, Chandrabhan Verma, and Jeenat Aslam. Elsevier, 2022. DOI: https://doi.org/10.1016/ B978-0-323-85405-4.00012-4

  3. [2]

    THE CORROSION OF METALS

    W. H. J. Vernon. “THE CORROSION OF METALS”. In: Journal of the Royal Society of Arts 97.4798 (1949)

  4. [3]

    Chapter 5 - Electrochemical corrosion

    R.A. Buchanan and E.E. Stansbury. “Chapter 5 - Electrochemical corrosion”. In: Handbook of Environmental Degradation of Materials. Ed. by Myer Kutz. Norwich, NY: William Andrew Publishing, 2005. DOI: https://doi.org/10.1016/B978-081551500-5.50007-0

  5. [4]

    What is Corrosion?

    Barbara Shaw and Robert Kelly. “What is Corrosion?” In: The Electrochemical Society Interface 15.1 (2006). DOI: 10.1149/2.F06061IF

  6. [5]

    Corrosion and Stress Corrosion Cracking Fundamentals

    Gary S. Was. “Corrosion and Stress Corrosion Cracking Fundamentals”. In: Fundamentals of Radiation Materials Science: Metals and Alloys. New York, NY: Springer New York, 2017.DOI: 10.1007/978-1-4939-3438-6_15

  7. [6]

    2 - Overview of nuclear materials and nuclear corrosion science and engineering

    D. F´eron. “2 - Overview of nuclear materials and nuclear corrosion science and engineering”. In:Nu- clear Corrosion Science and Engineering. Ed. by Damien F´eron. Woodhead Publishing Series in En- ergy. Woodhead Publishing, 2012. DOI: https://doi.org/10.1533/9780857095343. 1.31

  8. [7]

    Burnable Poisons in Nuclear Fuels

    K.W. Hesketh. “Burnable Poisons in Nuclear Fuels”. In: Encyclopedia of Materials: Science and Technology. Ed. by K.H. J ¨urgen Buschow et al. Oxford: Elsevier, 2002. DOI: https://doi. org/10.1016/B0-08-043152-6/01835-0

Show all 43 references
  1. [8]

    Materials challenges in nuclear energy

    S.J. Zinkle and G.S. Was. “Materials challenges in nuclear energy”. In:Acta Materialia 61.3 (2013). The Diamond Jubilee Issue. DOI: https://doi.org/10.1016/j.actamat.2012.11. 004

  2. [9]

    Hydrogen Embrittlement in Nuclear Power Systems

    George Young, Edward Richey, and David Morton. “Hydrogen Embrittlement in Nuclear Power Systems”. In: 2012. DOI: 10.1533/9780857093899.1.149

  3. [10]

    A review of irradiation assisted stress corrosion cracking

    P. Scott. “A review of irradiation assisted stress corrosion cracking”. In: Journal of Nuclear Materials 211.2 (1994). DOI: https://doi.org/10.1016/0022-3115(94)90360-3

  4. [11]

    Irradiation assisted corrosion and stress corrosion cracking (IAC/IASCC) in nuclear reactor systems and components

    Gary Was and Peter Andresen. “Irradiation assisted corrosion and stress corrosion cracking (IAC/IASCC) in nuclear reactor systems and components”. In: Nuclear Corrosion Science and Engineering (2012). DOI: 10.1533/9780857095343.2.131

  5. [12]

    Environmentally Assisted Cracking of Irradiated Metals and Alloys

    “Environmentally Assisted Cracking of Irradiated Metals and Alloys”. In: Fundamentals of Radia- tion Materials Science: Metals and Alloys. Berlin, Heidelberg: Springer Berlin Heidelberg, 2007. DOI: 10.1007/978-3-540-49472-0_15 . 8/10

  6. [13]

    The design, setup and operational testing of the irradiation and corrosion experiment (ICE)

    P. Hosemann et al. “The design, setup and operational testing of the irradiation and corrosion experiment (ICE)”. In: Journal of Nuclear Materials 376.3 (2008). Heavy Liquid Metal Cooled Reactors and Related Technologies. DOI: https : / / doi . org / 10 . 1016 / j . jnucmat . ...

  7. [14]

    Continuous Monitoring of Pure Fe Corrosion in Lead-Bismuth Eutectic Under Irradiation with Proton-Induced X-ray Emission Spectroscopy

    Franziska Schmidt et al. “Continuous Monitoring of Pure Fe Corrosion in Lead-Bismuth Eutectic Under Irradiation with Proton-Induced X-ray Emission Spectroscopy”. In: JOM 73.12 (2021). DOI: 10.1007/s11837-021-04954-x

  8. [15]

    Accelerated corrosion and oxide dissolution in 316L stainless steel irradiated in situ in high temperature water

    Stephen S. Raiman and Gary S. Was. “Accelerated corrosion and oxide dissolution in 316L stainless steel irradiated in situ in high temperature water”. In: Journal of Nuclear Materials 493 (2017). DOI: https://doi.org/10.1016/j.jnucmat.2017.05.043

  9. [16]

    Radiolysis driven changes to oxide stability during irradiation-corrosion of 316L stainless steel in high temperature water

    Stephen S. Raiman, David M. Bartels, and Gary S. Was. “Radiolysis driven changes to oxide stability during irradiation-corrosion of 316L stainless steel in high temperature water”. In: Journal of Nuclear Materials 493 (2017). DOI: https://doi.org/10.1016/j.jnucmat.2017. 05.042

  10. [17]

    An X-ray photo-electron spectroscopic study on the role of molybdenum in increasing the corrosion resistance of ferritic stainless steels in HC1

    K. Hashimoto, K. Asami, and K. Teramoto. “An X-ray photo-electron spectroscopic study on the role of molybdenum in increasing the corrosion resistance of ferritic stainless steels in HC1”. In: Corrosion Science 19.1 (1979). DOI: https://doi.org/10.1016/0010-938X(79) 90003-9

  11. [18]

    The mechanism of corrosion inhibition by chro- mate conversion coatings from x-ray absorption near edge spectroscopy (Xanes)

    M.W. Kendig, A.J. Davenport, and H.S. Isaacs. “The mechanism of corrosion inhibition by chro- mate conversion coatings from x-ray absorption near edge spectroscopy (Xanes)”. In: Corrosion Science 34.1 (1993). DOI: https://doi.org/10.1016/0010-938X(93)90257-H

  12. [19]

    Operando methods: A new era of electrochemistry

    Yao Yang et al. “Operando methods: A new era of electrochemistry”. In: Current Opinion in Electrochemistry 42 (2023). DOI: https : / / doi . org / 10 . 1016 / j . coelec . 2023 . 101403

  13. [20]

    Developments in X-ray tomography characterization for electro- chemical devices

    Thomas M.M. Heenan et al. “Developments in X-ray tomography characterization for electro- chemical devices”. In: Materials Today 31 (2019). DOI: https://doi.org/10.1016/j. mattod.2019.05.019

  14. [21]

    Coherent X-Ray Diffraction Imaging

    Jianwei Miao, Richard L. Sandberg, and Changyong Song. “Coherent X-Ray Diffraction Imaging”. In: IEEE Journal of Selected Topics in Quantum Electronics18.1 (2012). DOI: 10.1109/JSTQE. 2011.2157306

  15. [22]

    Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis

    Rafael A. Vicente et al. “Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis”. In: ACS Nano 15.4 (2021). DOI: 10.1021/acsnano.1c01080

  16. [23]

    Dark-field X-ray microscopy for multiscale structural characterization

    H. Simons et al. “Dark-field X-ray microscopy for multiscale structural characterization”. In: Nature Communications 6.1 (2015). DOI: 10.1038/ncomms7098

  17. [24]

    The ESRF dark-field x-ray microscope at ID06

    M Kutsal et al. “The ESRF dark-field x-ray microscope at ID06”. In: IOP Conference Series: Materials Science and Engineering 580.1 (2019). DOI: 10 . 1088 / 1757 - 899x / 580 / 1 / 012007

  18. [25]

    Direct Imaging of Hydrogen-Driven Dislocation and Strain Field Evolution in a Stainless Steel Grain

    David Yang et al. Direct Imaging of Hydrogen-Driven Dislocation and Strain Field Evolution in a Stainless Steel Grain. 2025

  19. [26]

    Formlabs Inc. Form 3+. 2025. URL: https://formlabs.com/store/3d-printers/ form-3-basic-package-without-service/#/ (visited on 06/03/2025)

  20. [28]

    X-Ray Irradiation Induced Strain Relaxation of Dewetted Ni Particles on Modified Si Substrate

    David Simonne et al. “X-Ray Irradiation Induced Strain Relaxation of Dewetted Ni Particles on Modified Si Substrate”. In: (2025). DOI: 10.2139/ssrn.5248343

  21. [29]

    Towards a quantitative determination of strain in Bragg Coherent X-ray Diffraction Imaging: artefacts and sign convention in reconstructions

    J´erˆome Carnis et al. “Towards a quantitative determination of strain in Bragg Coherent X-ray Diffraction Imaging: artefacts and sign convention in reconstructions”. In: Scientific Reports 9.1 (2019). DOI: 10.1038/s41598-019-53774-2

  22. [30]

    Cdiutils: A python package for X-ray Bragg Coherent Diffraction Imaging pro- cessing, analysis and visualisation workflows

    Clement Atlan. Cdiutils: A python package for X-ray Bragg Coherent Diffraction Imaging pro- cessing, analysis and visualisation workflows. Version v.0.1.4-beta. DOI: 10.5281/zenodo. 7656853. 9/10

  23. [31]

    Gwaihir: Jupyter Notebook graphical user interface for Bragg coherent diffraction imaging

    David Simonne et al. “ Gwaihir: Jupyter Notebook graphical user interface for Bragg coherent diffraction imaging”. In: Journal of Applied Crystallography 55.4 (2022). DOI: 10 . 1107 / S1600576722005854

  24. [32]

    PyNX: high-performance computing toolkit for coherent X-ray imaging based on operators

    Vincent Favre-Nicolin et al. “ PyNX: high-performance computing toolkit for coherent X-ray imaging based on operators”. In: Journal of Applied Crystallography53.5 (2020). DOI: 10.1107/ S1600576720010985

  25. [33]

    Reconstruction of an object from the modulus of its Fourier transform

    J. R. Fienup. “Reconstruction of an object from the modulus of its Fourier transform”. In: Opt. Lett. 3.1 (1978). DOI: 10.1364/OL.3.000027

  26. [34]

    Relaxed averaged alternating reflections for diffraction imaging

    D Russell Luke. “Relaxed averaged alternating reflections for diffraction imaging”. In: Inverse Problems 21.1 (2004). DOI: 10.1088/0266-5611/21/1/004

  27. [35]

    A practical algorithm for the determination of plane from image and diffraction pictures

    Ralph W Gerchberg. “A practical algorithm for the determination of plane from image and diffraction pictures”. In: Optik 35.2 (1972)

  28. [36]

    Equivalent of the point spread function for partially coherent imaging

    Shalin B. Mehta and Colin J. R. Sheppard. “Equivalent of the point spread function for partially coherent imaging”. In: Optica 2.8 (2015). DOI: 10.1364/OPTICA.2.000736

  29. [37]

    Free log-likelihood as an unbiased metric for coherent diffraction imaging

    Vincent Favre-Nicolin, Steven Leake, and Yuriy Chushkin. “Free log-likelihood as an unbiased metric for coherent diffraction imaging”. In: Scientific Reports 10.1 (2020). DOI: 10.1038/ s41598-020-57561-2

  30. [38]

    ParaView: An End-User Tool for Large Data Visualiza- tion

    J. Ahrens, Berk Geveci, and Charles Law. “ParaView: An End-User Tool for Large Data Visualiza- tion”. In: Visualization Handbook (2005)

  31. [39]

    Three-dimensional imaging of dislocation propagation during crystal growth and dissolution

    Jesse N. Clark et al. “Three-dimensional imaging of dislocation propagation during crystal growth and dissolution”. In: Nature Materials 14.8 (2015). DOI: 10.1038/nmat4320

  32. [40]

    Dissolving, trapping and detrapping mechanisms of hydrogen in bcc and fcc transition metals

    Yu-Wei You et al. “Dissolving, trapping and detrapping mechanisms of hydrogen in bcc and fcc transition metals”. In: AIP Advances 3.1 (2013). DOI: 10.1063/1.4789547

  33. [41]

    Hydrogen-Enhanced Vacancy Diffusion in Metals

    Jun-Ping Du et al. “Hydrogen-Enhanced Vacancy Diffusion in Metals”. In:The Journal of Physical Chemistry Letters 11.17 (2020). PMID: 32786653. DOI: 10.1021/acs.jpclett.0c01798

  34. [42]

    Thermodynamic analysis of the interaction between metal vacancies and hydrogen in bulk Cu

    Vasileios Fotopoulos, Ricardo Grau-Crespo, and Alexander L Shluger. “Thermodynamic analysis of the interaction between metal vacancies and hydrogen in bulk Cu”. In: Physical Chemistry Chemical Physics 25.13 (2023)

  35. [43]

    Defects Induced in Copper by Cathodic Charging of Hydrogen

    S. Nakahara and Y . Okinaka. “Defects Induced in Copper by Cathodic Charging of Hydrogen”. In: Journal of The Electrochemical Society 136.7 (1989). DOI: 10.1149/1.2097074. 10/10

Pith tools

Reviewed August 7, 2026 · model on record in the stance chip above.