Pith. sign in

REVIEW 1 cited by

The CaloCube calorimeter for high-energy cosmic-ray measurements in space: performance of a large-scale prototype

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2110.01561 v1 pith:WTME6DPB submitted 2021-10-04 physics.ins-det astro-ph.IMhep-ex

classification physics.ins-detastro-ph.IMhep-ex
keywords designspacecalocubecalorimetercubichigh-energyperformanceprototype
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the totalmass of the apparatus, which is amongst the most important constraints for a space mission. CaloCube is an homogeneous calorimeter whose basic geometry is cubic and isotropic, obtained by filling the cubic volume with small cubic scintillating crystals. In this way it is possible to detect particles arriving from every direction in space, thus maximizing the acceptance. This design summarizes a three-year R&D activity, aiming to both optimize and study the full-scale performance of the calorimeter, in the perspective of a cosmic-ray space mission, and investigate a viable technical design by means of the construction of several sizable prototypes. A large scale prototype, made of a mesh of 5x5x18 CsI(Tl) crystals, has been constructed and tested on high-energy particle beams at CERN SPS accelerator. In this paper we describe the CaloCube design and present the results relative to the response of the large scale prototype to electrons.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Development of a High-Resolution, High-Dynamic-Range Charge Detector for Ion Beam Monitoring

    physics.ins-det 2024-12 conditional novelty 6.0 of 10

    A prototype charge detector using silicon photodiodes and a high-dynamic-range ASIC achieves a charge resolution better than 0.3 Z units from Z=5 to 75 in CERN SPS ion beam tests.

Pith tools