pith. sign in

arxiv: 1810.13115 · v1 · pith:X4TAPDUFnew · submitted 2018-10-31 · ⚛️ physics.ins-det · nucl-ex

Directional fast neutron detection using a time projection chamber and plastic scintillation detectors

classification ⚛️ physics.ins-det nucl-ex
keywords neutrondetectiondetectorsfastprojectionscintillationchamberdirectional
0
0 comments X
read the original abstract

A new method for directional fast neutron detection is proposed based on a neutron time projection chamber (TPC) and position-sensitive plastic scintillation detectors. The detection system can efficiently locate the approximate location of a hot spot with 4{\pi} field-of-view using only the neutron TPC. Then, the system generates a high-resolution image of the hot spot using selected coincidence events in the TPC and the scintillation detectors. A prototype was built and tested using a Cf-252 source. An efficiency of 7.1x10-3 was achieved for fast searching. The angular resolution was 7.8{\deg} (full width at half maximum, FWHM) for high-resolution imaging using the simple back projection method.