Pith. sign in

REVIEW 1 cited by

CCAT-prime: The Optical Design for the Epoch of Reionization Spectrometer

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2208.09521 v1 pith:XVMEEKBL submitted 2022-08-19 astro-ph.IM astro-ph.CO

classification astro-ph.IMastro-ph.CO
keywords lensesdesignepochmoduleopticalreionizationachievebiconic
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity mapping of the 158 $\mu$m [CII] line in aggregates of star-forming galaxies between redshifts of 3.5 and 8 to trace the evolution of structure in the universe during the epoch of reionization. Here we present the optical design of the module including studies of the optical quality and other key parameters at the image surface. In order to achieve the required resolving power (R$\sim$100) with the FPI, it is important to have a highly collimated beam at the Lyot stop of the system; the optimization process to achieve this goal with four lenses instead of three as used in other Prime-Cam modules is outlined. As part of the optimization, we test the effect of replacing some of the aspheric lenses with biconic lenses in this Crossed Dragone design and find that the biconic lenses tend to improve the image quality across the focal plane of the module.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Spectral Data-cube Cleaning for CCAT Deep Spectroscopic Survey. I. Effect of correlated noise and filtering on the power spectrum

    astro-ph.GA 2026-07 conditional novelty 6.0 of 10

    The EoR-Spec Filter-and-Bin pipeline suppresses atmospheric 1/f noise by about four orders of magnitude and recovers the [CII]+CO power spectrum above k ~ 0.1 Mpc^-1, but suppresses large-scale modes below 20% transfe...

Pith tools