Pith. sign in

REVIEW 1 cited by

Line-of-sight shear in SLACS strong lenses I: shear and mass model parametrisations

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2501.16292 v3 pith:YCZGIDFL submitted 2025-01-27 astro-ph.CO astro-ph.GA

Line-of-sight shear in SLACS strong lenses I: shear and mass model parametrisations

classification astro-ph.CO astro-ph.GA
keywords shearmodellenslensesparametersstrongbeendegeneracies
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Inhomogeneities along the line of sight in strong gravitational lensing distort the images produced, in an effect called shear. If measurable, this shear may provide independent constraints on cosmological parameters, complementary to traditional cosmic shear. We model 23 strong gravitational lenses from the Sloan Lens ACS (SLACS) catalogue with the aim of measuring the line-of-sight (LOS) shear for the first time. We use the 'minimal model' for the LOS shear, which has been shown to be theoretically safe from degeneracies with lens model parameters, a finding which has been confirmed using mock data. We use the dolphin automated modelling pipeline, which uses the lenstronomy software as a modelling engine, to model our selected lenses. Across the 23 lenses, we measure the LOS shear with a mean magnitude of $0.056 \pm 0.013$. Neglecting the post-Born correction to the potential of the main deflector due to foreground shear leads to a propagation of degeneracies in the LOS shear measurement with other lens model parameters, and the inclusion of an octupole moment in the lens mass profile does not lead to shear measurements that are in better agreement with the expectations from weak lensing.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Line-of-sight shear in SLACS strong lenses II: validation tests with an extended sample

    astro-ph.CO 2025-12 conditional novelty 4.0

    Line-of-sight shear in 45 SLACS lenses is often larger than N-body expectations (mean |γ_LOS| ≈ 0.085–0.11), and adding mass octupoles or checking image properties does not remove the excess.