Quantitative measurement of the surface charge density
classification
❄️ cond-mat.mtrl-sci
keywords
chargedensitysurfaceelectrostaticsampleallowsalterambient
read the original abstract
We present a method of measuring the charge density on dielectric surfaces. Similar to electrostatic force microscopy we record the electrostatic interaction between the probe and the sample surface, but at large tip-sample distances. For calibration we use a pyroelectric sample which allows us to alter the surface charge density by a known amount via a controlled temperature change. For proof of principle we determined the surface charge density under ambient conditions of ferroelectric lithium niobate.
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.