pith. sign in

arxiv: cond-mat/9901245 · v1 · submitted 1999-01-22 · ❄️ cond-mat.mes-hall

Magnetoresistance, Micromagnetism, and Domain Wall Scattering in Epitaxial hcp Co Films

classification ❄️ cond-mat.mes-hall
keywords measurementsscatteringtemperaturedomainfilmslargemagnetoresistancematerial
0
0 comments X
read the original abstract

Large negative magnetoresistance (MR) observed in transport measurements of hcp Co films with stripe domains were recently reported and interpreted in terms of a novel domain wall (DW) scattering mechanism. Here detailed MR measurements, magnetic force microscopy, and micromagnetic calculations are combined to elucidate the origin of MR in this material. The large negative room temperature MR reported previously is shown to be due to ferromagnetic resistivity anisotropy. Measurements of the resistivity for currents parallel (CIW) and perpendicular to DWs (CPW) have been conducted as a function of temperature. Low temperature results show that any intrinsic effect of DWs scattering on MR of this material is very small compared to the anisotropic MR.

This paper has not been read by Pith yet.

discussion (0)