Study of the Hadron Shower Profiles with the Tile Hadron Calorimeter

High Energy Physics - Experiment · Submitted 22 Mar 1999

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The three-dimensional hadronic shower parametrisation have been suggested.

how it is stated · asserted 0.66 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv IDhep-ex/9903052 (version 1)
Pith ID6EJ33MSI, Pith's permanent record of this paper and its review
Citationet. al, Y.A. Kulchitsky. "Study of the Hadron Shower Profiles with the Tile Hadron Calorimeter." arXiv:hep-ex/9903052 (1999). https://pith.science/paper/6EJ33MSI
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 4,126 input tokens, $0.0002 reported.

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.11 · human participants 0.02 · controlled comparison 0.02 · randomized assignment 0.01 · states quantitative result 0.59 · compares with prior results 0.06 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

The lateral and longitudinal profiles of the hadronic showers detected by iron-scintillator tile hadron calorimeter with longitudinal tile configuration have been investigated. The results are based on 100 GeV pion beam data. Due to the beam scan provided many different beam impact locations with cells it is succeeded to obtain detailed picture of transverse shower behavior. The underlying radial energy densities for four depths and for overall calorimeter have been reconstructed. The three-dimensional hadronic shower parametrisation have been suggested.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 The lateral and longitudinal profiles of the hadronic showers detected by iron-scintillator tile hadron calorimeter with longitudinal tile configuration have been investigated. contribution 0.98 0.92 0.10 asserted 1.00
s1 The results are based on 100 GeV pion beam data. method 1.00 0.81 0.03 asserted 1.00
s2 Due to the beam scan provided many different beam impact locations with cells it is succeeded to obtain detailed picture of transverse shower behavior. method 0.99 0.89 0.05 asserted 1.00
s3 The underlying radial energy densities for four depths and for overall calorimeter have been reconstructed. result 0.95 0.93 0.17 asserted 1.00
s4 The three-dimensional hadronic shower parametrisation have been suggested. contribution 0.76 0.86 0.47 asserted 0.66

What kind of paper the classifier reports this is: empirical study 1.00 · evidence from observation or experiment 0.93.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

The lateral and longitudinal profiles of the hadronic showers detected by iron-scintillator tile hadron calorimeter with longitudinal tile configuration have been investigated. The results are based on 100 GeV pion beam data. Due to the beam scan provided many different beam impact locations with cells it is succeeded to obtain detailed picture of transverse shower behavior. The underlying radial energy densities for four depths and for overall calorimeter have been reconstructed. The three-dimensional hadronic shower parametrisation have been suggested.

Human review
How the literature uses it

Papers whose main result relates to this one's

How each label was checked · JSON

Found among the papers closest to this one by title and main claim. Pith's classifier compared each pair's main results and a second model family confirmed the relation; checked against two further families, shown conflicts agreed 118 times in 120 and shown same results 218 times in 239. The quoted sentence is the other paper's main claim.

States the same result 2 papers
  • The results presented here are useful for understanding the performance of iron-scintillator calorimeters, for developing fast simulations of hadronic showers, for many calorimetry problems requiring the integration of a shower energy deposition in a volume and for future calorimeter design.