Pith. Sign in

RECORD

Medium energy calorimetry at SND: techniques and performances on physics

High Energy Physics - Experiment · Submitted 19 Jul 1999

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The calorimeter performance is illustrated by examples from the current studies of different physical processes.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv IDhep-ex/9907038 (version 1)
Pith IDGPX666PB, Pith's permanent record of this paper and its review
CitationA.A.Drozdetsky, A.A.Korol, A.A.Salnikov, A.A.Valishev, A.D.Bukin, A.P.Lysenko, A.S.Zakharov, A.V.Berdyugin, A.V.Bozhenok, D.A.Bukin, E.E.Pyata, E.V.Pakhtusova, G.A.Kukartsev, I.A.Gaponenko, M.N.Achasov, M.S.Dubrovin, S.I.Dolinsky, S.I.Serednyakov, S.V.Burdin, S.V.Koshuba, T.V.Dimova, V.A.Sidorov, V.B.Golubev, V.M.Aulchenko, V.N.Ivanchenko, V.P.Druzhinin, V.V.Shary, Yu.S.Velikzhanin, Yu.V.Usov, Z.K.Silagadze. "Medium energy calorimetry at SND: techniques and performances on physics." arXiv:hep-ex/9907038 (1999). https://pith.science/paper/GPX666PB
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 3,684 input tokens, $0.0002 reported.

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.07 · human participants 0.02 · controlled comparison 0.02 · randomized assignment 0.01 · states quantitative result 0.69 · compares with prior results 0.06 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

SND (Spherical Neutral Detector) is a general purpose nonmagnetic detector, successfully operating at Novosibirsk VEPP-2M collider during last four years in the center of mass energy range from 400 MeV up to 1400 MeV. Its crucial part is a 3-layer, fine grained, spherical NaI(Tl) electromagnetic calorimeter consisted of 1632 individual counters. Here we present a detailed description of the calorimeter and its performance, including such topics as calorimeter design, electronics, calibration, energy and spatial resolutions, particle identification. The calorimeter performance is illustrated by examples from the current studies of different physical processes.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 SND (Spherical Neutral Detector) is a general purpose nonmagnetic detector, successfully operating at Novosibirsk VEPP-2M collider during last four years in the center of mass energy range from 400 MeV up to 1400 MeV. background 0.96 0.31 0.05 asserted 1.00
s1 Its crucial part is a 3-layer, fine grained, spherical NaI(Tl) electromagnetic calorimeter consisted of 1632 individual counters. method 0.88 0.30 0.04 asserted 1.00
s2 Here we present a detailed description of the calorimeter and its performance, including such topics as calorimeter design, electronics, calibration, energy and spatial resolutions, particle identification. contribution 0.99 0.74 0.07 asserted 0.97
s3 The calorimeter performance is illustrated by examples from the current studies of different physical processes. contribution 0.82 0.76 0.09 asserted 1.00

What kind of paper the classifier reports this is: method or tool 0.95 · evidence from observation or experiment 0.88.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

SND (Spherical Neutral Detector) is a general purpose nonmagnetic detector, successfully operating at Novosibirsk VEPP-2M collider during last four years in the center of mass energy range from 400 MeV up to 1400 MeV. Its crucial part is a 3-layer, fine grained, spherical NaI(Tl) electromagnetic calorimeter consisted of 1632 individual counters. Here we present a detailed description of the calorimeter and its performance, including such topics as calorimeter design, electronics, calibration, energy and spatial resolutions, particle identification. The calorimeter performance is illustrated by examples from the current studies of different physical processes.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.