RECORD
Non-compensation of an Electromagnetic Compartment of a Combined Calorimeter
High Energy Physics - Experiment · Submitted 23 Nov 1999
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
The method of extraction of the $e/h$ ratio, the degree of non-compensation, of the electromagnetic compartment of the combined calorimeter is suggested. The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data. This value agrees with the prediction that $e/h > 1.7$ for this electromagnetic calorimeter.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | The method of extraction of the $e/h$ ratio, the degree of non-compensation, of the electromagnetic compartment of the combined calorimeter is suggested. | method 0.63 | 0.64 | 0.13 | hedged possibility 0.66 |
| s1 | The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data. | result 1.00 | 0.93 | 0.50 | asserted 1.00 |
| s2 | This value agrees with the prediction that $e/h > 1.7$ for this electromagnetic calorimeter. | interpretation 0.97 | 0.43 | 0.27 | asserted 0.75 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
The method of extraction of the $e/h$ ratio, the degree of non-compensation, of the electromagnetic compartment of the combined calorimeter is suggested. The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data. This value agrees with the prediction that $e/h > 1.7$ for this electromagnetic calorimeter.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.