Pith. Sign in

RECORD

The e/h Method of Energy Reconstruction for Combined Calorimeter

High Energy Physics - Experiment · Submitted 7 Dec 1999

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The method has been tested on the basis of the 1996 test beam data of the combined calorimeter and demonstrated the correctness of the reconstruction of the mean values of energies.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv IDhep-ex/9912014 (version 1)
Citation2), Belarus; (2) JINR, Dubna, Minsk, M.V. Kuzmin (1, National Academy of Sciences, Russia), V.B. Vinogradov (2) ((1) Institute of Physics, Y.A. Kulchitsky (1. "The e/h Method of Energy Reconstruction for Combined Calorimeter." arXiv:hep-ex/9912014 (1999). https://pith.science/paper/hep-ex/9912014
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 4,267 input tokens, $0.0002 reported.

What the abstract itself states, as probabilities: claims first 0.07 · states limitation 0.18 · human participants 0.02 · controlled comparison 0.04 · randomized assignment 0.01 · states quantitative result 0.98 · compares with prior results 0.10 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

The new simple method of the energy reconstruction for a combined calorimeter, which we called the e/h method, is suggested. It uses only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. The method has been tested on the basis of the 1996 test beam data of the combined calorimeter and demonstrated the correctness of the reconstruction of the mean values of energies. The obtained fractional energy resolution is $[(58\pm3)%/\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E$. This algorithm can be used for the fast energy reconstruction in the first level trigger.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 The new simple method of the energy reconstruction for a combined calorimeter, which we called the e/h method, is suggested. contribution 1.00 0.87 0.19 asserted 0.66
s1 It uses only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. method 0.99 0.51 0.12 asserted 1.00
s2 The method has been tested on the basis of the 1996 test beam data of the combined calorimeter and demonstrated the correctness of the reconstruction of the mean values of energies. result 0.47 0.93 0.26 asserted 1.00
s3 The obtained fractional energy resolution is $[(58\pm3)%/\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E$. result 1.00 0.93 0.23 asserted 1.00
s4 This algorithm can be used for the fast energy reconstruction in the first level trigger. interpretation 0.74 0.46 0.15 hedged possibility 0.82

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from analysis of existing data 0.76.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

The new simple method of the energy reconstruction for a combined calorimeter, which we called the e/h method, is suggested. It uses only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. The method has been tested on the basis of the 1996 test beam data of the combined calorimeter and demonstrated the correctness of the reconstruction of the mean values of energies. The obtained fractional energy resolution is $[(58\pm3)%/\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E$. This algorithm can be used for the fast energy reconstruction in the first level trigger.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.