We report on a new test of Lorentz invariance performed by comparing the resonance frequencies of two orthogonal cryogenic optical resonators subject to Earth's rotation over 1 year. For a possible anisotropy of the speed of light c, we obtain 2.6 +/- 1.7 parts in 10^15. Within the Robertson-Mansouri-Sexl test theory, this implies an isotropy violation parameter beta - delta - 1/2 of -2.2 +/- 1.5 parts in 10^9, about three times lower than the best previous result. Within the general extension of the standard model of particle physics, we extract limits on 7 parameters at accuracies down to a part in 10^15, improving the best previous result by about two orders of magnitude.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The Confrontation between General Relativity and Experiment

    gr-qc 2014-03 accept novelty 2.0