Pith. Sign in

RECORD

Optical Doppler shift measurement using a rotating mirror

Physics Education · Submitted 24 Jul 2006

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim Using a rotating mirror, in which one beam is reflected from the advancing side and the other beam is reflected from the receding part of a rotating mirror, can overcome many of the noise generating effects.

how it is stated · asserted 0.72 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv IDphysics/0607213 (version 2)
Pith IDDNLCFL77, Pith's permanent record of this paper and its review
CitationL. Bernal, L. Bilbao. "Optical Doppler shift measurement using a rotating mirror." arXiv:physics/0607213 (2006). https://pith.science/paper/DNLCFL77
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 4,291 input tokens.

What the abstract itself states, as probabilities: claims first 0.05 · states limitation 0.14 · human participants 0.02 · controlled comparison 0.04 · randomized assignment 0.01 · states quantitative result 0.04 · compares with prior results 0.74 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v2. Results and the main claim are underlined; .

Optical Doppler shift demonstration experiments are not a simple task since the light source cannot usually be moved in a sufficiently smooth and uniform manner to keep the level of noise well below of that of the signal. For that reason most demonstration experiments are usually performed with sound or with microwaves. Previous work have been reported using a moving mirror in order to produce a moving light source, but small perturbation of its trajectory, as small as the optical wavelength, can produce a large noise. Using a rotating mirror, in which one beam is reflected from the advancing side and the other beam is reflected from the receding part of a rotating mirror, can overcome many of the noise generating effects. In the present work we report the construction and operation of a demonstration apparatus for measuring optical Doppler shift based on a rotating mirror.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 Optical Doppler shift demonstration experiments are not a simple task since the light source cannot usually be moved in a sufficiently smooth and uniform manner to keep the level of noise well below of that of the signal. background 0.99 0.08 0.03 asserted 0.99
s1 For that reason most demonstration experiments are usually performed with sound or with microwaves. background 1.00 0.05 0.02 asserted 1.00
s2 Previous work have been reported using a moving mirror in order to produce a moving light source, but small perturbation of its trajectory, as small as the optical wavelength, can produce a large noise. background 0.97 0.04 0.04 asserted 1.00
s3 Using a rotating mirror, in which one beam is reflected from the advancing side and the other beam is reflected from the receding part of a rotating mirror, can overcome many of the noise generating effects. method 0.84 0.25 0.35 asserted 0.72
s4 In the present work we report the construction and operation of a demonstration apparatus for measuring optical Doppler shift based on a rotating mirror. contribution 1.00 0.96 0.40 asserted 0.99

What kind of paper the classifier reports this is: method or tool 0.98 · evidence from observation or experiment 0.98.

What was examined, and what was not

sources read
  • arXiv listing abstract v2
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

Optical Doppler shift demonstration experiments are not a simple task since the light source cannot usually be moved in a sufficiently smooth and uniform manner to keep the level of noise well below of that of the signal. For that reason most demonstration experiments are usually performed with sound or with microwaves. Previous work have been reported using a moving mirror in order to produce a moving light source, but small perturbation of its trajectory, as small as the optical wavelength, can produce a large noise. Using a rotating mirror, in which one beam is reflected from the advancing side and the other beam is reflected from the receding part of a rotating mirror, can overcome many of the noise generating effects. In the present work we report the construction and operation of a demonstration apparatus for measuring optical Doppler shift based on a rotating mirror.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.