pith. sign in

arxiv: 0803.0470 · v3 · submitted 2008-03-04 · 🪐 quant-ph

Feedback cooling of the normal modes of a massive electromechanical system to submillikelvin temperature

classification 🪐 quant-ph
keywords temperaturecoolingfeedbacknormalquantumsquidbathelectromechanical
0
0 comments X
read the original abstract

We apply a feedback cooling technique to simultaneously cool the three electromechanical normal modes of the ton-scale resonant-bar gravitational wave detector AURIGA. The measuring system is based on a dc Superconducting Quantum Interference Device (SQUID) amplifier, and the feedback cooling is applied electronically to the input circuit of the SQUID. Starting from a bath temperature of 4.2 K, we achieve a minimum temperature of 0.17 mK for the coolest normal mode. The same technique, implemented in a dedicated experiment at subkelvin bath temperature and with a quantum limited SQUID, could allow to approach the quantum ground state of a kilogram-scale mechanical resonator.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. True and apparent motion of optomechanical resonators, with applications to feedback cooling of gravitational wave detector test masses

    quant-ph 2024-08 unverdicted novelty 4.0

    Extends prior two-photon formalism to compute true motion and optimal cooling in multi-DOF GW detector test masses, finding sub-unity occupation numbers possible over the oscillator bandwidth for common definitions.