REVIEW 2 cited by
The effect of non-Gaussianity on error predictions for the Epoch of Reionization (EoR) 21-cm power spectrum
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
The effect of non-Gaussianity on error predictions for the Epoch of Reionization (EoR) 21-cm power spectrum
read the original abstract
The Epoch of Reionization (EoR) 21-cm signal is expected to become increasingly non-Gaussian as reionization proceeds. We have used semi-numerical simulations to study how this affects the error predictions for the EoR 21-cm power spectrum. We expect $SNR=\sqrt{N_k}$ for a Gaussian random field where $N_k$ is the number of Fourier modes in each $k$ bin. We find that non-Gaussianity is important at high $SNR$ where it imposes an upper limit $[SNR]_l$. For a fixed volume $V$, it is not possible to achieve $SNR > [SNR]_l$ even if $N_k$ is increased. The value of $[SNR]_l$ falls as reionization proceeds, dropping from $\sim 500$ at $\bar{x}_{HI} = 0.8-0.9$ to $\sim 10$ at $\bar{x}_{HI} = 0.15 $ for a $[150.08\, {\rm Mpc}]^3$ simulation. We show that it is possible to interpret $[SNR]_l$ in terms of the trispectrum, and we expect $[SNR]_l \propto \sqrt{V}$ if the volume is increased. For $SNR \ll [SNR]_l$ we find $SNR = \sqrt{N_k}/A $ with $A \sim 0.95 - 1.75$, roughly consistent with the Gaussian prediction. We present a fitting formula for the $SNR$ as a function of $N_k$, with two parameters $A$ and $[SNR]_l$ that have to be determined using simulations. Our results are relevant for predicting the sensitivity of different instruments to measure the EoR 21-cm power spectrum, which till date have been largely based on the Gaussian assumption.
Forward citations
Cited by 2 Pith papers
-
21cmEMUv3: a hybrid diffusion-LSTM emulator of 21cmFAST summary observables
21cmEMUv3 emulates the cylindrical 21cm power spectrum via score-based diffusion and six other 21cmFAST observables via LSTM networks at sub-percent accuracy, then uses the emulator to infer a lower limit on soft-band...
-
CosmoUiT: A Vision Transformer-UNet Hybrid for Fast and Accurate Emulation of 21-cm Maps from the Epoch of Reionization
A Vision Transformer-UNet hybrid emulates 3D EoR 21-cm cubes conditioned on reionization parameters, matching simulated large-scale power spectra with mild small-scale suppression.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.