Pith. sign in

REVIEW 1 cited by

Focusing characteristics of a 4$\pi$ parabolic mirror light-matter interface

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1609.06884 v2 pith:LIJA4FW4 submitted 2016-09-22 quant-ph physics.optics

classification quant-phphysics.optics
keywords focusingmirrorparabolicanglesolidallowserrorsinterface
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Focusing with a 4$\pi$ parabolic mirror allows for concentrating light from nearly the complete solid angle, whereas focusing with a single microscope objective limits the angle cone used for focusing to half solid angle at maximum. Increasing the solid angle by using deep parabolic mirrors comes at the cost of adding more complexity to the mirror's fabrication process and might introduce errors that reduce the focusing quality. To determine these errors, we experimentally examine the focusing properties of a 4$\pi$ parabolic mirror that was produced by single-point diamond turning. The properties are characterized with a single $^{174}$Yb$^{+}$ ion as a mobile point scatterer. The ion is trapped in a vacuum environment with a movable high optical access Paul trap. We demonstrate an effective focal spot size of 209 nm in lateral and 551 nm in axial direction. Such tight focusing allows us to build an efficient light-matter interface. Our findings agree with numerical simulations incorporating a finite ion temperature and interferometrically measured wavefront aberrations induced by the parabolic mirror. We point at further technological improvements and discuss the general scope of applications of a 4$\pi$ parabolic mirror.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Feedback Cooling and Thermometry of a Single Trapped Ion Using a Knife Edge

    quant-ph 2025-12 conditional novelty 6.0 of 10

    Knife-edge imaging of a single ion's fluorescence enables feedback cooling to 432±56 µK, nominally below the 470 µK Doppler limit, and up to nine-fold temperature reduction at high saturation.

Pith tools