Pith. sign in

REVIEW 2 cited by

Radiation resistant LGAD design

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1802.01745 v4 pith:C7HVTN5I submitted 2018-02-06 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords boronacceptorinitiallgadradiationremovaldopinggallium
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

In this paper, we report on the radiation resistance of 50-micron thick LGAD detectors manufactured at the Fondazione Bruno Kessler employing several different doping combinations of the gain layer. LGAD detectors with gain layer doping of Boron, Boron low-diffusion, Gallium, Carbonated Boron and Carbonated Gallium have been designed and successfully produced. These sensors have been exposed to neutron fluences up to $\phi_n \sim 3 \cdot 10^{16}\; n/cm^2$ and to proton fluences up to $\phi_p \sim 9\cdot10^{15}\; p/cm^2$ to test their radiation resistance. The experimental results show that Gallium-doped LGADs are more heavily affected by initial acceptor removal than Boron-doped LGAD, while the presence of Carbon reduces initial acceptor removal both for Gallium and Boron doping. Boron low-diffusion shows a higher radiation resistance than that of standard Boron implant, indicating a dependence of the initial acceptor removal mechanism upon the implant width. This study also demonstrates that proton irradiation is at least twice more effective in producing initial acceptor removal, making proton irradiation far more damaging than neutron irradiation.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Properties of carbon-infused silicon LGAD devices after non-uniform irradiation with 24 GeV/c protons

    physics.ins-det 2024-12 conditional novelty 6.0 of 10

    First IV/CV measurements of carbon-infused LGAD sensors after non-uniform 24 GeV/c proton irradiation up to 1e16 p/cm2 show a common operating voltage may remain viable despite a roughly tenfold dose gradient.

  2. Tracking particles at fluences 5-10 $\cdot$1E16 $n_{eq}$/cm$^2$

    physics.ins-det 2019-08 conditional novelty 5.0 of 10

    Thin LGAD sensors could deliver signals above 1 fC at fluences up to 1e17 n_eq/cm2 by shifting charge multiplication from the gain layer to the radiation-doped bulk.