Pith. sign in

REVIEW 1 cited by

Calibration of the CMS hadron calorimeters using proton-proton collision data at sqrt{s} = 13 TeV

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1910.00079 v2 pith:HAZILFLC submitted 2019-09-30 physics.ins-det hep-ex

Calibration of the CMS hadron calorimeters using proton-proton collision data at sqrt{s} = 13 TeV

classification physics.ins-det hep-ex
keywords calorimetersdatacalibrationenergycalorimetercollectedhadronscale
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities $|\eta| <$ 3 and are positioned inside a solenoidal magnet. An outer calorimeter, outside the magnet coil, covers $|\eta| <$ 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to $|\eta| <$ 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at $\sqrt{s} =$ 7, 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the early 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb$^{-1}$. The intercalibration of channels exploits the approximate uniformity of energy deposit over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z $\to$ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Measurement of the $\gamma\gamma \to \tau \tau$ cross section and constraints on the anomalous magnetic moment of the $\tau$ lepton in ultraperipheral PbPb collisions at $\sqrt{s_\mathrm{NN}}$ = 5.02 TeV

    nucl-ex 2026-07 conditional novelty 5.0

    CMS measures gamma-gamma -> tau+tau- in PbPb UPCs and constrains the tau anomalous magnetic moment to -0.039 < a_tau < 0.032 (95% CL), with a fiducial cross-section of 555+60-14 microbarns.