Pith. sign in

REVIEW 1 cited by

A revised view of the linear polarization in the subparsec core of M87 at 7 mm

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2107.13243 v2 pith:ACANKE7H submitted 2021-07-28 astro-ph.HE

A revised view of the linear polarization in the subparsec core of M87 at 7 mm

classification astro-ph.HE
keywords polarizationcalibrationlinearcorecomplexdatainstrumentallpcal
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The linear polarization images of the jet in the giant elliptical galaxy M87 have previously been observed with Very Long Baseline Array at 7 mm. They exhibit a complex polarization structure surrounding the optically thick and compact subparsec-scale core. However, given the low level of linear polarization in the core, it is required to verify that this complex structure does not originate from residual instrumental polarization signals in the data. We have performed a new analysis of the same data sets observed in four epochs by using the Generalized Polarization CALibration pipeline (GPCAL). This novel instrumental polarization calibration pipeline overcomes the limitations of LPCAL, a conventional calibration tool used in the previous M87 studies. The resulting images show a compact linear polarization structure with its peak nearly coincident with the total intensity peak, which is significantly different from the results of previous studies. The core linear polarization is characterized as fractional polarization of $\sim0.2-0.6$% and polarization angles of $\sim66-92^\circ$, showing moderate variability. We demonstrate that, based on tests with synthetic data sets, LPCAL using calibrators having complex polarization structures cannot achieve sufficient calibration accuracy to obtain the true polarization image of M87 due to a breakdown of the "similarity approximation". We find that GPCAL obtains more accurate D-terms than LPCAL by using observed closure traces of calibrators that are insensitive to both antenna gain and polarization leakage corruptions. This study suggests that polarization imaging of very weakly polarized sources has become possible with the advanced instrumental polarization calibration techniques.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Dynamics and geometry of the inner sub-parsec-scale jet in 3C 279 observed with the Event Horizon Telescope

    astro-ph.GA 2026-07 conditional novelty 5.0

    EHT 2021 images of 3C 279 reveal an intrinsic, sideways-elongated jet base whose components move at apparent speeds up to 10c, implying a sub-parsec bend toward the observer and viewing angles below one degree.