REVIEW 1 cited by
Investigating X-ray Emission in the GeV-emitting Compact Symmetric Objects PKS 1718-649 and TXS 1146+596
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Investigating X-ray Emission in the GeV-emitting Compact Symmetric Objects PKS 1718-649 and TXS 1146+596
read the original abstract
Compact Symmetric Objects (CSOs) are thought to represent the first step in the evolutionary path of radio galaxies. In this work, we investigate the X-ray emission of two CSOs confirmed to emit at GeV energies: PKS 1718-649 and TXS 1146+596. Unveiling the origin of their observed high-energy emission is crucial to establishing the physical parameters of the radio source and understanding how CSOs interact with the surrounding medium. We combined archival and new NuSTAR observations of PKS 1718-649 and TXS 1146+596 to have a broadband X-ray coverage. For both sources, we model the broadband spectral energy distribution, from radio band up to $\gamma$-rays, to derive their physical parameters. We also discuss the role of the ambient medium in confining the source expansion, which we investigate using X-ray obscuration. For the first time, we report on X-ray detections of PKS 1718-649 and 1146+596 with NuSTAR at energies higher than 10 keV. Combining Chandra and NuSTAR observations of TXS 1146+596, we reveal the presence of a multi-temperature thermal component dominating the soft X-ray spectrum, and we interpret this finding as indicative of an AGN feedback process in action in this source. In addition, we show that two emitting electrons populations are necessary to reproduce the observed broadband spectral energy distribution of TXS 1146+596: in our models, the X-ray emission could be produced either by synchrotron radiation or by a weak X-ray corona or an ADAF-type emission. Interestingly, an additional X-ray component, i.e. a weak corona, is also required for PKS 1718-649. Moreover, we argue that heavily obscured, and possibly frustrated, sources tend to show different radio sizes with respect to unobscured, free to expand, ones.
Forward citations
Cited by 1 Pith paper
-
Searching for $\gamma$-ray emission from a bona fide Compact Symmetric Object sample: a $\gamma$-ray signal near GB6 J0906+4124
No bona fide CSO in a 73-source sample is firmly detected in 16 years of Fermi-LAT data; a ~4σ signal near GB6 J0906+4124 is a plausible but unconfirmed counterpart.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.