Pith. sign in

REVIEW 2 cited by

The SRG/eROSITA All-Sky Survey: SRG/eROSITA cross-calibration with Chandra and XMM-Newton using galaxy cluster gas temperatures

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2401.17297 v2 pith:4LAISUS4 submitted 2024-01-30 astro-ph.CO astro-ph.HE

The SRG/eROSITA All-Sky Survey: SRG/eROSITA cross-calibration with Chandra and XMM-Newton using galaxy cluster gas temperatures

classification astro-ph.CO astro-ph.HE
keywords erositaclusterchandraxmm-newtonacisepicbandgalaxy
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Galaxy cluster gas temperatures ($T$) play a crucial role in many cosmological and astrophysical studies. However, it has been shown that $T$ measurements can vary between different X-ray telescopes. These $T$ biases can propagate to several cluster applications for which $T$ can be used. Thus, it is important to accurately cross-calibrate X-ray instruments to account for systematic biases. In this work, we present the cross-calibration between SRG/eROSITA and Chandra/ACIS, and between SRG/eROSITA and XMM-Newton/EPIC, using for the first time a large sample of galaxy cluster $T$. To do so, we use the first eROSITA All-Sky Survey data and a large X-ray flux-limited cluster catalog. We measure X-ray $T$ for 186 independent cluster regions with both SRG/eROSITA and Chandra/ACIS in a self-consistent way, for three energy bands; 0.7-7 keV (full), 0.5-4 keV (soft), and 1.5-7 keV (hard). We do the same with SRG/eROSITA and XMM-Newton/EPIC for 71 different cluster regions and all three bands. We find that SRG/eROSITA measures systematically lower $T$ than the other two instruments. For the full band, SRG/eROSITA returns 20$\%$ and 14$\%$ lower $T$ than Chandra/ACIS and XMM-Newton/EPIC respectively, when the two latter instruments measure $k_{\text{B}}T\approx 3$ keV each. The discrepancy increases to 38\% and 32\% when Chandra/ACIS and XMM-Newton/EPIC measure $k_{\text{B}}T\approx 10$ keV respectively. For low-$T$ galaxy groups, the discrepancy becomes milder. The soft band shows a marginally lower discrepancy than the full band. In the hard band, the cross-calibration of SRG/eROSITA and the other instruments show stronger differences. We could not identify any possible systematic biases that significantly alleviated the tension. Finally, we provide conversion factors between SRG/eROSITA, Chandra/ACIS, and XMM-Newton/EPIC $T$ which will be beneficial for future cluster studies.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. What's Missing in AGN Feedback? Lessons learnt from Magneticum, IllustrisTNG and Simba

    astro-ph.GA 2026-07 conditional novelty 6.0

    No current simulation simultaneously reproduces observed halo hot-gas fractions and local galaxy star-formation/quenching demographics; strong AGN feedback overquenches, weak feedback retains too much gas.

  2. New constraints on cosmic anisotropy from galaxy clusters using an improved dipole fitting method

    astro-ph.CO 2026-02 unverdicted novelty 5.0

    Galaxy cluster observations yield two preferred directions with cosmic anisotropy amplitude of about 5.3 times 10 to the minus 4 at roughly 1 sigma overall significance, though higher in the XMM-Newton subsample.