Pith. sign in

REVIEW 1 cited by

FAST survey of H I and OH absorption towards extragalactic radio sources

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2406.20026 v1 pith:L5MKRWZY submitted 2024-06-28 astro-ph.GA

FAST survey of H I and OH absorption towards extragalactic radio sources

classification astro-ph.GA
keywords radiosourcestimesabsorptiondetectioncolumnredshifttowards
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Neutral atomic hydrogen and molecular gas in the host galaxies of radio active galactic nuclei (AGN) can be traced using H I 21-cm and OH-1667 MHz absorption lines to understand the fueling and feedback processes. We present the results of an H I and OH absorption survey with the Five-hundred-meter Aperture Spherical radio Telescope (FAST) towards 40 radio sources of low-intermediate radio luminosity ($\sim$10$^{23}$-10$^{26}$ W Hz$^{-1}$ at 1.4 GHz), red mid-infrared color (W2[4.6 $\mu$m]$-$W3[12 $\mu$m] $>$ 2.5 mag) and redshift up to 0.35. From 13 sources with good data at H I observing frequencies, we report the detection of H I absorption towards 8 sources, 5 of which are new detections including 4 in the redshift range 0.25 to 0.35. Our detection rates are consistent with our previous results with dependence on the star-formation history of the host galaxy reflected in the mid-infrared \textit{WISE} W2$-$W3 colors and the compactness of the radio source. We find no significant dependence of detection rates on radio luminosity or redshift. We also find that H I column densities are anti-correlated with the low-frequency spectral indices ($\alpha_{\rm 150 MHz}^{\rm 1.4 GHz}$, $S_{\nu}\propto \nu^{-\alpha}$). We do not have any detection from 23 sources with good data at OH observing frequencies. However, by stacking the spectra we estimate the 3$\sigma$ upper limit of OH column density to be 2.27$\times$10$^{14}$$T_{\rm ex}$/10 K $\times$1/$f_{\rm c}$ cm$^{-2}$. By stacking the OH spectra for 7 associated H I absorbers, we get a 3$\sigma$ upper limit of 3.47$\times$10$^{14}$ $T_{\rm ex}$/10 K $\times$1/$f_{\rm c}$ cm$^{-2}$ on OH column density and 1.78$\times$10$^{-7}$ on [OH]/[H I] ratio.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The FAST HI 21-cm Absorption Blind Survey. III. OH Absorption Search in the 21-cm Absorber Sample and Continued HI Absorption Search

    astro-ph.GA 2026-07 accept novelty 5.0

    A blind FAST survey of 41 HI absorbers re-detected the known OH absorber PKS 1413+135, found no new OH, and set [OH]/[HI] upper limits near 1e-8.