REVIEW 1 cited by
Performance of an instrumented baffle placed at the entrance of Virgo's end mirror vacuum tower during O5
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Performance of an instrumented baffle placed at the entrance of Virgo's end mirror vacuum tower during O5
read the original abstract
In this article, we present results on the simulated performance of an instrumented baffle installed at the entrance of the vacuum towers hosting the end mirrors of Virgo's main Fabry-P\'erot cavities. The installation of instrumented baffles is part of the Advanced Virgo Plus upgrade in time for the O5 observing run. They were originally envisaged to be suspended, mounted on new payloads and surrounding new larger end mirrors. The current Virgo upgrade plan includes the replacement of the mirrors with new ones of better quality and same dimensions, leaving the installation of new payloads and larger end mirrors to a post-O5 upgrade phase still to be defined. Here we demonstrate that placing the instrumented baffles just beyond the cryotrap gate valve and in front of the end mirrors would be equally effective for monitoring scattered light inside the cavities. This new location, more than a meter away from the mirror, further reduces the risk of contamination and any potential interference with the mirrors, preserves the full capability to monitor scattered light, and decouples the instrumented baffle timeline from the plans for installing large mirrors in the experiment. We provide an estimate of the light distribution the baffles would encounter under both nominal and non-nominal conditions, as well as an assessment of the scattered light noise introduced by these baffles in this new location, confirming that they would not compromise Virgo's sensitivity.
Forward citations
Cited by 1 Pith paper
-
Optomechanical transfer factors for scattered light noise estimations in the beamtubes of ground-based gravitational wave detectors
Scattered-light noise coupling to strain readout is derived as full optomechanical transfer factors, recovering legacy models only in phase-dominated regimes and substantially revising Einstein Telescope low-frequency...
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.