Pith. sign in

REVIEW 1 cited by

Quality Concerns Caused by Quality Control -- deformation of silicon strip detector modules in thermal cycling tests

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2503.03133 v1 pith:YDDMGRLT submitted 2025-03-05 hep-ex physics.ins-det

Quality Concerns Caused by Quality Control -- deformation of silicon strip detector modules in thermal cycling tests

classification hep-ex physics.ins-det
keywords modulesdetectormodulecyclingqualitystriptemperaturethermal
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35C and +40C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Cracking under pressure --- investigating mitigation approaches for silicon fractures on ATLAS strip tracker petals at cold temperatures

    physics.ins-det 2026-07 conditional novelty 4.0

    Improved Nominal SE4445 adhesive patterns for ATLAS ITk petal modules prevent sensor cracking down to −45 °C, with only a few-percent crack rate after −55 °C thermal cycles.