Pith. sign in

REVIEW 1 cited by

Atomic thermometry in optical lattice clocks

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2508.08164 v2 pith:2RS53A7B submitted 2025-08-11 physics.atom-ph cond-mat.quant-gas

Atomic thermometry in optical lattice clocks

classification physics.atom-ph cond-mat.quant-gas
keywords atomiclatticetemperatureopticalclocksaccuratecoolingharmonic
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Accurate measurement of atomic temperature is fundamental for a wide range of applications, from quantum sensing to precision metrology. In optical lattice clocks, precise characterization of atomic temperature is required to minimize systematic uncertainties at the $10^{-18}$ level. In this work, we investigate atomic temperature measurements in the ytterbium optical lattice clock developed at INRIM, IT-Yb1, employing sideband and Doppler spectroscopy across a wide range of trapping conditions. By implementing clock-line-mediated Sisyphus cooling [Phys. Rev. Lett. 133, 053401 (2024)], we reduce the atomic temperature and enable operation at shallower lattice depths down to $D = 50E_{R}$. We compare temperature estimates obtained from the harmonic oscillator model with those derived using a Born-Oppenheimer-based approach [Phys. Rev. A 101, 053416 (2020)], which is expected to provide a more accurate description of atomic motion in both longitudinal and radial directions, especially for hotter atoms whose motion deviates from the harmonic regime. Discrepancies up to a factor of two in extracted temperatures are observed depending on the chosen model. We assess the impact of these modeling differences on the evaluation of lattice shifts and find relative frequency deviations up to $8\times10^{-17}$. Even though extended Sisyphus cooling reduces these inconsistencies to the $1\times10^{-18}$ level, residual biases may still limit the accuracy of optical lattice clocks.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Interspecies clock comparison below $5 \times 10^{-18}$ uncertainty with a transportable clock

    physics.atom-ph 2026-08 accept novelty 6.0

    The Yb+(E3)/Sr optical frequency ratio is measured with 4.3e-18 fractional uncertainty, a 3.5x improvement over the previous best, using a transportable Sr clock.