pith. machine review for the scientific record. sign in

arxiv: gr-qc/0209039 · v2 · submitted 2002-09-12 · 🌀 gr-qc

Recognition: unknown

The LISA Optimal Sensitivity

Authors on Pith no claims yet
classification 🌀 gr-qc
keywords lisasensitivitysqrtimprovementinterferometriclightmichelsontravel-time
0
0 comments X
read the original abstract

The multiple Doppler readouts available on the Laser Interferometer Space Antenna (LISA) permit simultaneous formation of several interferometric observables. All these observables are independent of laser frequency fluctuations and have different couplings to gravitational waves and to the various LISA instrumental noises. Within the functional space of interferometric combinations LISA will be able to synthesize, we have identified a triplet of interferometric combinations that show optimally combined sensitivity. As an application of the method, we computed the sensitivity improvement for sinusoidal sources in the nominal, equal-arm LISA configuration. In the part of the Fourier band where the period of the wave is longer than the typical light travel-time across LISA, the sensitivity gain over a single Michelson interferometer is equal to $\sqrt{2}$. In the mid-band region, where the LISA Michelson combination has its best sensitivity, the improvement over the Michelson sensitivity is slightly better than $\sqrt{2}$, and the frequency band of best sensitivity is broadened. For frequencies greater than the reciprocal of the light travel-time, the sensitivity improvement is oscillatory and $\sim \sqrt{3}$, but can be greater than $\sqrt{3}$ near frequencies that are integer multiples of the inverse of the one-way light travel-time in the LISA arm.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Parameter-estimation bias induced by transient orbital resonances in extreme-mass-ratio inspirals

    gr-qc 2026-04 unverdicted novelty 5.0

    Neglecting transient orbital resonances in EMRIs causes significant SNR losses and biases in recovered parameters, with the sign and amplitude of resonance-induced changes to integrals of motion being critical.

  2. Probing Kerr Symmetry Breaking with LISA Extreme-Mass-Ratio Inspirals

    gr-qc 2026-04 unverdicted novelty 5.0

    LISA EMRIs can constrain deviations from Kerr equatorial symmetry to 10^{-2} and axial symmetry to 10^{-3} using Analytic Kludge waveforms and Fisher analysis.

  3. Are Black Holes Fuzzballs? Probing Horizon-Scale Structure with LISA

    hep-th 2026-04 unverdicted novelty 5.0

    LISA can constrain non-axisymmetric mass quadrupole deformations at the 10^{-3} level and axisymmetric mass octupole deformations at the 10^{-2} level in EMRI signals to test fuzzball proposals.