Pith. sign in

REVIEW 1 cited by

ESCAPE project: fundamental detection limits of JWST/NIRCam coronographic observations

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2409.03485 v1 pith:AYWJAXEG submitted 2024-09-05 astro-ph.IM astro-ph.EP

classification astro-ph.IMastro-ph.EP
keywords noisecontrastfundamentallimitmcmcpost-processingdeepernircam
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

In this study, we explored the fundamental contrast limit of NIRCam coronagraphy observations, representing the achievable performance with post-processing techniques. This limit is influenced by photon noise and readout noise, with complex noise propagation through post-processing methods like principal component analysis. We employed two approaches: developing a formula based on simplified scenarios and using Markov Chain Monte Carlo (MCMC) methods, assuming Gaussian noise properties and uncorrelated pixel noise. Tested on datasets HIP\,65426, AF\,Lep, and HD\,114174, the MCMC method provided accurate but computationally intensive estimates. The analytical approach offered quick, reliable estimates closely matching MCMC results in simpler scenarios. Our findings showed the fundamental contrast curve is significantly deeper than the current achievable contrast limit obtained with post-processing techniques at shorter separations, being 10 times deeper at $0.5''$ and 4 times deeper at $1''$. At greater separations, increased exposure time improves sensitivity, with the transition between photon and readout noise dominance occurring between $2''$ and $3''$. We conclude the analytical approach is a reliable estimate of the fundamental contrast limit, offering a faster alternative to MCMC. These results emphasize the potential for greater sensitivity at shorter separations, highlighting the need for improved or new post-processing techniques to enhance JWST NIRCam sensitivity or contrast curve.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Commissioning of the MIRAC-5 Mid-Infrared Instrument on the MMT

    astro-ph.IM 2024-12 conditional novelty 6.0 of 10

    Commissioning of the MIRAC-5 mid-infrared camera on the MMT yields roughly 10% total throughput, near-diffraction-limited N-band images, and calibrated sensitivity estimates for exoplanet science.

Pith tools