REVIEW 4 major objections 3 minor 19 references
Vision Transformers for Kidney Stone Image Classification: A Comparative Study with CNNs
T0 review · 4 major / 3 minor · reviewed 2026-08-05 · deepseek-v4-flash
Pith's one-line read The paper claims that a Vision Transformer pretrained on ImageNet-21k classifies kidney stone subtypes from endoscopic images more accurately than a ResNet50 CNN pretrained on ImageNet-1k, with the largest margin on the hardest section-patc
desk verdict Useful benchmark, but the ViT superiority claim is a pretraining-scale artifact until a ResNet50-21k baseline is added. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The central object is the ViT-base model with the standard patch-and-self-attention pipeline: the image is cut into fixed-size patches, each patch is linearly embedded, and multi-head self-attention re-weights every patch against every other patch before classification. It supplies global context in a single pass, which the paper says is what lets the model form compact, well-separated clusters under lighting and view variability. The ImageNet-21k pretraining is a second, equally load-bearing component: it is the version that yields the headline numbers, while the same ViT pretrained on ImageNet-1k or from scratch performs much worse.
What would settle it
Run the identical split and training protocol with a ResNet50 pretrained on ImageNet-21k (or both models initialized from the same 21k checkpoint) and compare on all six dataset-by-view subsets. If the 21k-pretrained CNN matches or exceeds the ViT, the architectural conclusion is falsified and the observed gap was pretraining data, not self-attention.
Extended reading notes
Core claim
The authors' positive claim is that transformer-based models, specifically ViT-base pretrained on ImageNet-21k, classify kidney stone subtypes from endoscopic images more accurately and with better feature structure than the ResNet50 CNN baseline. The support consists of an ablation across two datasets and three view types, embedding visualizations with silhouette scores, intra-class distance tables, confusion matrices, and a qualitative sample comparison. The authors attribute the results to self-attention's global patch-level context, which lets the model separate visually ambiguous stone subtypes that trip up convolutional features.
Load-bearing premise
The central comparison is not architecture-only: the ViT uses ImageNet-21k pretraining while the ResNet uses ImageNet-1k, and on one surface-view subset the ResNet already leads; the paper's conclusion assumes that pretraining scale is not doing most of the work.
Editorial extensions
If this is right
- Automated stone subtype recognition could be built around a single pretrained ViT rather than task-specific CNN pipelines.
- The large margins on hard Section patches suggest transformer features hold up where lighting and view artifacts break CNN embeddings.
- Compact ViT embeddings, with lower intra-class distances and higher silhouette scores, imply better retrievability of visually similar stone subtypes.
- If deployed, the system could give urologists an immediate visual read during ureteroscopy, reducing the need to extract fragments for infrared laboratory analysis.
Reading between the lines
- Editorial inference: the headline gap is as much about pretraining scale as about architecture. ViT-base pretrained on ImageNet-1k trails ResNet50-ImageNet-1k on five of the six subsets in Table 3, so the 21k pretraining is doing consequential work.
- Editorial inference: the direct falsifying experiment is to train a ResNet50 with ImageNet-21k pretraining under the same protocol and compare; if the CNN matches or exceeds the ViT, the observed advantage is a pretraining-data effect rather than a self-attention effect.
- Editorial inference: the paper's 'consistently outperformed' phrasing is stronger than the table shows—on Dataset A surface views the ViT-21k scores 76.8% versus ResNet50's 79.6%—so the claim depends on which subsets are highlighted.
Signed reviews
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper compares Vision Transformer (ViT) and CNN (ResNet) models for kidney stone subtype classification on two ex vivo image datasets, one from CCD cameras and one from flexible ureteroscopes. Across six view subsets, the authors report accuracy, F1, precision, and recall for ResNet50/ResNet152 and ViT-base/ViT-small under several pretraining conditions (ImageNet-1k, ImageNet-21k, from scratch), together with feature-embedding analyses based on t-SNE, silhouette scores, and intra-class distances. The central claim is that ViT architectures—particularly ViT-base pretrained on ImageNet-21k—provide superior classification performance and more discriminative embeddings than CNNs.
Significance. If the claim were established under controlled conditions, the result would be practically relevant for automated endoscopic kidney stone recognition, and the paper's combination of a multi-subset benchmark with an ablation over pretraining is a useful empirical contribution. I see no circularity: the headline numbers are measured outcomes on held-out test images. The main weakness is that the architecture comparison is confounded with pretraining data scale: the paper compares ViT pretrained on ImageNet-21k against ResNet50 pretrained on ImageNet-1k, and its own matched-pretraining rows largely contradict the superiority claim. The paper also reports headline abstract numbers that differ from the corresponding entries in Table 3. The strengths are the breadth of the benchmark and the inclusion of several quantitative embedding diagnostics, but the central comparative conclusion needs additional controlled experiments or a substantially more cautious framing.
major comments (4)
- [Table 3] The paper's central claim—that ViT architectures provide superior classification performance (Sec. 7)—rests on comparing ViT-base pretrained on ImageNet-21k with ResNet50 pretrained on ImageNet-1k. This confounds architecture with pretraining data scale. In the matched ImageNet-1k rows, ViT-base is worse than ResNet50 on five of six subsets (A MIX 0.624 vs 0.784; A SEC 0.657 vs 0.809; A SUR 0.492 vs 0.796; B MIX 0.769 vs 0.850; B SUR 0.704 vs 0.864), and better only on B SEC (0.739 vs 0.645). An ImageNet-21k-pretrained CNN baseline (e.g., ResNet50-21k) is needed before attributing the improvement to the transformer architecture; otherwise the results support a pretraining-scale effect, not an architecture effect.
- [Abstract vs. Table 3] The headline examples in the abstract do not match the reported table. The abstract states 87.1% accuracy for the CCD mixed-view subset and 95.2% accuracy/95.1% F1 for the endoscopic section subset, but Table 3 reports 0.890 for A MIX (ViT-base/21k) and 0.957/0.958 for B SEC. If these figures come from a different configuration or table, that configuration must be cited; as printed, the key numbers are not reproducible from the paper's main table.
- [Abstract and Sec. 7] Even under the authors' chosen (unmatched) comparison, the statement that ViT 'consistently outperformed' ResNet50 is contradicted by the A SUR row: ResNet50/ImageNet-1k achieves 0.796 accuracy vs 0.768 for ViT-base/ImageNet-21k. The conclusions should be qualified to name the subsets and pretraining conditions for which ViT wins, and should not claim general superiority.
- [Sec. 6.2, Fig. 5, Table 4] The embedding comparison ('same experimental conditions') is also affected by the pretraining confound. If the ViT features come from the ImageNet-21k model and the CNN features from the ImageNet-1k model, the higher silhouette scores and lower intra-class distances may reflect pretraining scale rather than architecture. Please specify which rows of Table 3 are used, and either repeat the embedding analysis with matched pretraining or discuss the confound explicitly.
minor comments (3)
- [Sec. 1.2] The statement that ViTs 'require less data for training because their self-attention mechanism efficiently captures global contextual relationships' is not supported and appears contradicted by Table 3: from-scratch ViT-base attains 0.209--0.505 across subsets, whereas from-scratch ResNet50 attains 0.583--0.773. Please remove or substantiate this claim.
- [Table 3] To assess whether the reported differences are stable, please add confidence intervals, repeated-run variance, or at least the number of test images per subset. The current point estimates, especially for small subsets, do not by themselves establish 'consistent' superiority.
- [Table 3 header] The table header appears garbled (e.g., 'Subv敲獩潮'). Please ensure the final PDF typesets the header correctly.
Circularity Check
No significant circularity; the ViT-vs-CNN claim is an empirical benchmark, with a non-circular pretraining confound.
full rationale
The paper's central claim is an empirical benchmark result: it reports test-set accuracy, F1, precision, and recall for ViT and ResNet variants trained on two ex vivo datasets. No parameter is fitted to a subset of the test data and then renamed as a prediction; the headline numbers in Table 3 are measured on held-out images and are not constructed from the inputs by any equation. The datasets and some baselines come from the authors' prior work (refs 6, 13, 14, 15), but self-supplied data are not circular because the test metrics are external outcomes of trained models. The closest concern is the comparison ViT-21k vs ResNet50-1k, which confounds architecture with pretraining scale; at matched ImageNet-1k pretraining, ViT loses on five of six subsets, and A SUR contradicts the abstract's 'consistently outperformed.' That is an internal-validity/external-validity problem, not a derivation that reduces to its own inputs. No uniqueness theorem, ansatz-by-citation, or renamed known result appears. The ablation study actually provides the counter-evidence internally, so the claim is not forced by construction.
Assumptions & free parameters
free parameters (2)
- Training hyperparameters (learning rate, epochs, batch size, augmentation)
- ImageNet-21k pretraining applied only to ViT
assumptions (3)
- domain assumption ImageNet-pretrained features transfer to ex vivo endoscopic kidney stone images
- domain assumption Ground-truth stone subtypes (Daudon classification) in Datasets A and B are correct
- domain assumption Train/test patches are drawn IID with no leakage between overlapping regions of the same stone image
Cite this review
Pith. "Pith review of Vision Transformers for Kidney Stone Image Classification: A Comparative Study with CNNs." pith.science (2026). https://pith.science/paper/4HTGEZGX
@misc{pith2026250813461,
author = {Pith},
title = {Pith review of: Vision Transformers for Kidney Stone Image Classification: A Comparative Study with CNNs},
year = {2026},
howpublished = {\url{https://pith.science/paper/4HTGEZGX}},
note = {Machine review of arXiv:2508.13461}
}
read the original abstract
Kidney stone classification from endoscopic images is critical for personalized treatment and recurrence prevention. While convolutional neural networks (CNNs) have shown promise in this task, their limited ability to capture long-range dependencies can hinder performance under variable imaging conditions. This study presents a comparative analysis between Vision Transformers (ViTs) and CNN-based models, evaluating their performance on two ex vivo datasets comprising CCD camera and flexible ureteroscope images. The ViT-base model pretrained on ImageNet-21k consistently outperformed a ResNet50 baseline across multiple imaging conditions. For instance, in the most visually complex subset (Section patches from endoscopic images), the ViT model achieved 95.2% accuracy and 95.1% F1-score, compared to 64.5% and 59.3% with ResNet50. In the mixed-view subset from CCD-camera images, ViT reached 87.1% accuracy versus 78.4% with CNN. These improvements extend across precision and recall as well. The results demonstrate that ViT-based architectures provide superior classification performance and offer a scalable alternative to conventional CNNs for kidney stone image analysis.
Reference graph
Works this paper leans on
-
[1]
npj Digital Medicine5(1), 184 (2022) 3
Ali, S.: Where do we stand in ai for endoscopic image analysis? deciphering gaps and future directions. npj Digital Medicine5(1), 184 (2022) 3
work page 2022
-
[2]
European Urology Focus 7(1), 13–21 (2021) 2, 4, 5, 8 Kidney Stone Recognition with ViT 17
Corrales, M., Doizi, S., Barghouthy, Y., Traxer, O., Daudon, M.: Classification of stones according to michel daudon: a narrative review. European Urology Focus 7(1), 13–21 (2021) 2, 4, 5, 8 Kidney Stone Recognition with ViT 17
work page 2021
-
[3]
Comptes Rendus Chimie 19(11-12), 1470–1491 (2016) 2
Daudon, M., Dessombz, A., Frochot, V., Letavernier, E., Haymann, J.P., Jungers, P., Bazin, D.: Comprehensive morpho-constitutional analysis of urinary stones im- proves etiological diagnosis and therapeutic strategy of nephrolithiasis. Comptes Rendus Chimie 19(11-12), 1470–1491 (2016) 2
work page 2016
-
[4]
Nephron Physiology98(2), p31–p36 (2004) 1
Daudon,M.,Jungers,P.:Clinicalvalueofcrystalluriaandquantitativemorphocon- stitutional analysis of urinary calculi. Nephron Physiology98(2), p31–p36 (2004) 1
work page 2004
-
[5]
arXiv preprint arXiv:2010.11929 (2020) 6, 7, 9
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al.: An image is worth 16x16 words: Transformers for image recognition at scale. arXiv preprint arXiv:2010.11929 (2020) 6, 7, 9
arXiv 2010
-
[6]
BJU international130(6), 786–798 (2022) 4, 5, 8
El Beze, J., Mazeaud, C., Daul, C., Ochoa-Ruiz, G., Daudon, M., Eschwège, P., Hubert, J.: Evaluation and understanding of automated urinary stone recognition methods. BJU international130(6), 786–798 (2022) 4, 5, 8
work page 2022
-
[7]
survey results practice committee of the afu lithiasis completed in 2011
Estrade, V., Bensalah, K., Bringer, J., Chabannes, E., Carpentier, X., Conort, P., Denis, E., Dore, B., Gautier, J., Hadjadj, H., et al.: Place of the flexible ureterorenoscopy first choice for the treatment of kidney stones. survey results practice committee of the afu lithiasis completed in 2011. Progres en Urologie: Journal de L’association Francaise D...
work page 2011
-
[8]
PROGRES EN UROLO- GIE 27(2), F26–F35 (2017) 1, 3
Estrade, V., Daudon, M., Traxer, O., Meria, P.: Why should urologist recognize uri- nary stone and how? the basis of endoscopic recognition. PROGRES EN UROLO- GIE 27(2), F26–F35 (2017) 1, 3
work page 2017
Show all 19 references
-
[9]
BJU international128(3), 319–330 (2021) 3
Estrade, V., Denis de Senneville, B., Meria, P., Almeras, C., Bladou, F., Bernhard, J.C., Robert, G., Traxer, O., Daudon, M.: Toward improved endoscopic examina- tion of urinary stones: a concordance study between endoscopic digital pictures vs microscopy. BJU international128...
2021
-
[10]
arXiv preprint arXiv:2408.05952 (2024) 3
Habib, G., Singh, D., Malik, I.A., Lall, B.: Optimizing vision transformers with data-free knowledge transfer. arXiv preprint arXiv:2408.05952 (2024) 3
2024 arXiv
-
[11]
Scientific Reports 14(1), 12567 (2024) 3
Halder, A., Gharami, S., Sadhu, P., Singh, P.K., Woźniak, M., Ijaz, M.F.: Imple- menting vision transformer for classifying 2d biomedical images. Scientific Reports 14(1), 12567 (2024) 3
2024
-
[12]
Khan, A.H., Imran, S., Talati, J., Jafri, L.: Fourier transform infrared spectroscopy foranalysisofkidneystones.InvestigativeandClinicalUrology 59(1),32–37(2018) 2
2018
-
[13]
In: 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
Lopez, F., Varelo, A., Hinojosa, O., Mendez, M., Trinh, D.H., ElBeze, Y., Hubert, J., Estrade, V., Gonzalez, M., Ochoa, G., et al.: Assessing deep learning methods for the identification of kidney stones in endoscopic images. In: 2021 43rd Annual International Conference of th...
2021
-
[14]
IEEE Access12, 10736–10759 (2024) 3, 6
Lopez-Tiro, F., Estrade, V., Hubert, J., Flores-Araiza, D., Gonzalez-Mendoza, M., Ochoa, G., Daul, C.: On the in vivo recognition of kidney stones using machine learning. IEEE Access12, 10736–10759 (2024) 3, 6
2024
-
[15]
Lopez-Tiro, F., Flores-Araiza, D., Betancur-Rengifo, J.P., Reyes-Amezcua, I., Hu- bert, J., Ochoa-Ruiz, G., Daul, C.: Boosting kidney stone identification in endo- scopicimagesusingtwo-steptransferlearning.In:Mexicaninternationalconference on artificial intelligence. pp. 131–1...
2023
-
[16]
arXiv preprint arXiv:1711.05101 (2017) 7 18 I
Loshchilov, I., Hutter, F.: Decoupled weight decay regularization. arXiv preprint arXiv:1711.05101 (2017) 7 18 I. Reyes et al
2017 arXiv
-
[17]
Journal of Endourology35(6), 931– 936 (2021) 3
Taratkin, M., Laukhtina, E., Singla, N., Tarasov, A., Alekseeva, T., Enikeev, M., Enikeev, D.: How lasers ablate stones: in vitro study of laser lithotripsy (ho: Yag and tm-fiber lasers) in different environments. Journal of Endourology35(6), 931– 936 (2021) 3
2021
-
[18]
BioMedical Engineering OnLine23(1), 27 (2024) 3
Yin, Y., Tang, Z., Weng, H.: Application of visual transformer in renal image analysis. BioMedical Engineering OnLine23(1), 27 (2024) 3
2024
-
[19]
Journal of clinical medicine research 11(3), 208 (2019) 1
Zeng, J., Wang, S., Zhong, L., Huang, Z., Zeng, Y., Zheng, D., Zou, W., Lai, H.: A retrospective study of kidney stone recurrence in adults. Journal of clinical medicine research 11(3), 208 (2019) 1
2019
Reviewed August 5, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.