Study of Residual Product Nuclide Yields from 0.1, 0.2, 0.8, and 2.6 GeV Proton-Irradiated nat-Hg Targets
classification
⚛️ nucl-ex
nucl-th
keywords
codenuclideproductresidualtargetsusedyieldscalculated
read the original abstract
The direct gamma-spectrometry method is used to measure more than 350 residual product nuclide yields from 0.1, 0.2, 0.8, and 2.6 GeV proton irradiated HgO targets. The gamma-spectrometer resolution is of 1.8 keV at the 1332 keV gamma-line. The resultant gamma-spectra are processed by the GENIE-2000 code. The gamma-lines are identified, and the cross-sections calculated, by the ITEP-designed SIGMA code using the PCNUDAT radioactive database. The 27-Al(p,x)Na-22 reaction is used as monitor. The experimental results are compared with calculations by the LAHET, CEM95, CEM2k, INUCL, CASCADE, and YIELDX codes.