Pith. Sign in

RECORD

The 2-3 mixing and mass split: atmospheric neutrinos and magnetized spectrometers

High Energy Physics - Phenomenology · Submitted 2 Dec 2010

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim ICAL can measure the difference of $\Delta m_{32}^2$ in $\nu$ and $\bar\nu$ channels (the CPT test) with accuracy $0.8\times 10^{-4}$ eV$^2$ (3$\sigma$) with 1 Mton$\cdot$yr exposure, and the present MINOS result can be excluded at $>5\sigma$ confidence level.

how it is stated · asserted 0.99 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1012.0360 (version 3)
Pith IDIIHEY2PB, Pith's permanent record of this paper and its review
CitationAbhijit Samanta, A. Yu. Smirnov. "The 2-3 mixing and mass split: atmospheric neutrinos and magnetized spectrometers." arXiv:1012.0360 (2010). https://pith.science/paper/IIHEY2PB
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,973 input tokens, $0.0003 reported.

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.76 · human participants 0.02 · controlled comparison 0.11 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.88 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v3. Results and the main claim are underlined; .

We study dependence of the atmospheric $\nu_\mu$ and $\bar{\nu}_\mu$ fluxes on the deviations of the 2-3 mixing from maximal, $|45^\circ - \theta_{23}|$, on the $\theta_{23}$-octant and on the neutrino mass splitting $\Delta m_{32}^2$. Analytic expressions for the $\theta_{23}-$deviation effect and the octant asymmetry are derived. We present conservative estimations of sensitivities of the iron (magnetized) calorimeter detectors (ICAL) to these parameters. ICAL can establish the $\theta_{23}$-deviation at higher than 3$\sigma$ confidence level if $| 45^\circ - \theta_{23}| > 6^{\circ}$ with the exposure of 1 Mton$\cdot$yr. Sensitivity to the octant is low for zero or very small 1-3 mixing, but it can be substantially enhanced for $\theta_{13} > 3^\circ$. ICAL can measure the difference of $\Delta m_{32}^2$ in $\nu$ and $\bar\nu$ channels (the CPT test) with accuracy $0.8\times 10^{-4}$ eV$^2$ (3$\sigma$) with 1 Mton$\cdot$yr exposure, and the present MINOS result can be excluded at $>5\sigma$ confidence level. We discuss possible ways to further improve sensitivity of the magnetized spectrometers.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We study dependence of the atmospheric $\nu_\mu$ and $\bar{\nu}_\mu$ fluxes on the deviations of the 2-3 mixing from maximal, $|45^\circ - \theta_{23}|$, on the $\theta_{23}$-octant and on the neutrino mass splitting $\Delta m_{32}^2$. contribution 0.99 0.72 0.04 asserted 0.80
s1 Analytic expressions for the $\theta_{23}-$deviation effect and the octant asymmetry are derived. contribution 0.53 0.94 0.05 asserted 1.00
s2 We present conservative estimations of sensitivities of the iron (magnetized) calorimeter detectors (ICAL) to these parameters. contribution 0.91 0.90 0.07 asserted 0.93
s3 ICAL can establish the $\theta_{23}$-deviation at higher than 3$\sigma$ confidence level if $| 45^\circ - \theta_{23}| > 6^{\circ}$ with the exposure of 1 Mton$\cdot$yr. result 1.00 0.85 0.25 asserted 0.77
s4 Sensitivity to the octant is low for zero or very small 1-3 mixing, but it can be substantially enhanced for $\theta_{13} > 3^\circ$. result 0.98 0.83 0.08 asserted 0.67
s5 ICAL can measure the difference of $\Delta m_{32}^2$ in $\nu$ and $\bar\nu$ channels (the CPT test) with accuracy $0.8\times 10^{-4}$ eV$^2$ (3$\sigma$) with 1 Mton$\cdot$yr exposure, and the present MINOS result can be excluded at $>5\sigma$ confidence level. result 1.00 0.82 0.31 asserted 0.99
s6 We discuss possible ways to further improve sensitivity of the magnetized spectrometers. future work 0.97 0.45 0.03 hedged possibility 0.60

What kind of paper the classifier reports this is: theoretical result 0.78 · evidence from proof or derivation 0.64.

What was examined, and what was not

sources read
  • arXiv listing abstract v3
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We study dependence of the atmospheric $\nu_\mu$ and $\bar{\nu}_\mu$ fluxes on the deviations of the 2-3 mixing from maximal, $|45^\circ - \theta_{23}|$, on the $\theta_{23}$-octant and on the neutrino mass splitting $\Delta m_{32}^2$. Analytic expressions for the $\theta_{23}-$deviation effect and the octant asymmetry are derived. We present conservative estimations of sensitivities of the iron (magnetized) calorimeter detectors (ICAL) to these parameters. ICAL can establish the $\theta_{23}$-deviation at higher than 3$\sigma$ confidence level if $| 45^\circ - \theta_{23}| > 6^{\circ}$ with the exposure of 1 Mton$\cdot$yr. Sensitivity to the octant is low for zero or very small 1-3 mixing, but it can be substantially enhanced for $\theta_{13} > 3^\circ$. ICAL can measure the difference of $\Delta m_{32}^2$ in $\nu$ and $\bar\nu$ channels (the CPT test) with accuracy $0.8\times 10^{-4}$ eV$^2$ (3$\sigma$) with 1 Mton$\cdot$yr exposure, and the present MINOS result can be excluded at $>5\sigma$ confidence level. We discuss possible ways to further improve sensitivity of the magnetized spectrometers.

Human review
References
How the literature uses it

11 arXiv papers cite this in 15 sentences

Each citing sentence is taken from the citing paper's LaTeX source and typed by Pith's classifier. A label appears at probability 0.8 or more (0.95 for support), a contest at 0.7 or more; the quoted words are the citing authors'. How each label was checked · JSON

Papers citing it · 7 sentences without a confident label

Contests it 1 paper
Cites it as background 5 papers

What it cites · 21 sentences without a confident label

Uses the method or tool of 1 paper
  • To evaluate physics potential of the atmospheric neutrino studies with a magnetized ICAL detector we generated the atmospheric neutrino events and considered the muon energy and direction (directly measurable quantities) using event generator NUANCE-v3 [ref] .

    The nuance Neutrino Simulation, and the Future · The $χ^2$ analysis for ICAL · 1.00

Uses data or values from 7 papers
Cites as background 7 papers

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.