RECORD
High data-rate atom interferometer for measuring acceleration
Quantum Physics · Submitted 21 Sep 2011
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments. The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. | contribution 1.00 | 0.96 | 0.32 | asserted 1.00 |
| s1 | The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. | result 0.95 | 0.91 | 0.13 | asserted 1.00 |
| s2 | Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments. | interpretation 0.96 | 0.85 | 0.65 | asserted 0.96 |
| s3 | The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another. | interpretation 0.98 | 0.79 | 0.14 | asserted 0.81 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments. The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.