Pith. Sign in

RECORD

High data-rate atom interferometer for measuring acceleration

Quantum Physics · Submitted 21 Sep 2011

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments.

how it is stated · asserted 0.96 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1109.4610 (version 1)
Pith IDVI3ES6BL, Pith's permanent record of this paper and its review
CitationAkash V. Rakholia, Grant W. Biedermann, Hayden J. McGuinness. "High data-rate atom interferometer for measuring acceleration." arXiv:1109.4610 (2011). https://pith.science/paper/VI3ES6BL
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 3,587 input tokens, $0.0002 reported.

What the abstract itself states, as probabilities: claims first 0.06 · states limitation 0.18 · human participants 0.02 · controlled comparison 0.03 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.16 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments. The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. contribution 1.00 0.96 0.32 asserted 1.00
s1 The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. result 0.95 0.91 0.13 asserted 1.00
s2 Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments. interpretation 0.96 0.85 0.65 asserted 0.96
s3 The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another. interpretation 0.98 0.79 0.14 asserted 0.81

What kind of paper the classifier reports this is: method or tool 0.99 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our method offers a dramatic increase in data rate and demonstrates a path to new applications in highly dynamic environments. The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.