Pith. sign in

REVIEW 1 cited by

Realistic polarizing Sagnac topology with DC readout for the Einstein Telescope

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1303.5236 v2 pith:HW25QEZF submitted 2013-03-21 physics.ins-det astro-ph.IMgr-qcphysics.optics

classification physics.ins-detastro-ph.IMgr-qcphysics.optics
keywords detectorssagnaccurrentdesigninterferometerpolarizingrealisticcavities
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

The Einstein Telescope (ET) is a proposed future gravitational wave detector. Its design is original, using a triangular orientation of three detectors and a xylophone configuration, splitting each detector into one high-frequency and one low-frequency system. In other aspects the current design retains the dual-recycled Michelson interferometer typical of current detectors, such as Advanced LIGO. In this paper, we investigate the feasibility of replacing the low-frequency part of the ET detectors with a Sagnac interferometer. We show that a Sagnac interferometer, using realistic optical parameters based on the ET design, could provide a similar level of radiation pressure noise suppression without the need for a signal recycling mirror and the extensive filter cavities. We consider the practical issues of a realistic, power-recycled Sagnac, using linear arm cavities and polarizing optics. In particular, we investigate the effects of nonperfect polarizing optics and propose a new method for the generation of a local oscillator field similar to the DC readout scheme of current detectors.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Improving calibration accuracy with torque coupled gravity field calibrator for sub-Hz gravitational wave observation in CHRONOS

    gr-qc 2026-02 conditional novelty 6.0 of 10

    A torque-coupled gravity calibrator for CHRONOS is calculated to give a calibration SNR density of 4.25e3 at 1 Hz with 0.24% fractional systematic uncertainty.

Pith tools