The authors' main claim A concentration gradient was found, which indicates that the Gd2O3 amount diminishes towards the edges of the pellets.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
A transversal mapping of the Gd concentration was measured in UO2-Gd2O3 nuclear fuel pellets by electron paramagnetic resonance spectroscopy (EPR). The quantification was made from the comparison with a Gd2O3 reference sample. The nominal concentration in the pellets is UO2: 7.5 % Gd2O3. A concentration gradient was found, which indicates that the Gd2O3 amount diminishes towards the edges of the pellets. The concentration varies from (9.3 +/- 0.5)% in the center to (5.8 +/- 0.3)% in one of the edges. The method was found to be particularly suitable for the precise mapping of the distribution of Gd3+ ions in the UO2 matrix.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | A transversal mapping of the Gd concentration was measured in UO2-Gd2O3 nuclear fuel pellets by electron paramagnetic resonance spectroscopy (EPR). | method 0.52 | 0.92 | 0.07 | asserted 1.00 |
| s1 | The quantification was made from the comparison with a Gd2O3 reference sample. | method 1.00 | 0.90 | 0.04 | asserted 1.00 |
| s2 | The nominal concentration in the pellets is UO2: 7.5 % Gd2O3. | background 0.76 | 0.25 | 0.03 | asserted 1.00 |
| s3 | A concentration gradient was found, which indicates that the Gd2O3 amount diminishes towards the edges of the pellets. | result 0.75 | 0.95 | 0.54 | asserted 0.53 |
| s4 | The concentration varies from (9.3 +/- 0.5)% in the center to (5.8 +/- 0.3)% in one of the edges. | result 1.00 | 0.95 | 0.32 | asserted 1.00 |
| s5 | The method was found to be particularly suitable for the precise mapping of the distribution of Gd3+ ions in the UO2 matrix. | interpretation 0.82 | 0.90 | 0.48 | asserted 0.99 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
A transversal mapping of the Gd concentration was measured in UO2-Gd2O3 nuclear fuel pellets by electron paramagnetic resonance spectroscopy (EPR). The quantification was made from the comparison with a Gd2O3 reference sample. The nominal concentration in the pellets is UO2: 7.5 % Gd2O3. A concentration gradient was found, which indicates that the Gd2O3 amount diminishes towards the edges of the pellets. The concentration varies from (9.3 +/- 0.5)% in the center to (5.8 +/- 0.3)% in one of the edges. The method was found to be particularly suitable for the precise mapping of the distribution of Gd3+ ions in the UO2 matrix.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.