Pith. Sign in

RECORD

High-resolution absorption cross sections of C$_{2}$H$_{6}$ at elevated temperatures

Earth and Planetary Astrophysics · Submitted 23 Oct 2015

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim These new measurements are the first high-resolution infrared C$_{2}$H$_{6}$ cross sections at elevated temperatures.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1510.07010 (version 1)
Pith IDLZMDG2EA, Pith's permanent record of this paper and its review
CitationEric Buzan, Michael Dulick, Peter F. Bernath, Robert J. Hargreaves. "High-resolution absorption cross sections of C$_{2}$H$_{6}$ at elevated temperatures." arXiv:1510.07010 (2015). https://pith.science/paper/LZMDG2EA
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 3,592 input tokens.

What the abstract itself states, as probabilities: claims first 0.96 · states limitation 0.09 · human participants 0.01 · controlled comparison 0.05 · randomized assignment 0.01 · states quantitative result 0.78 · compares with prior results 0.43 · mentions code or data availability 0.03.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

Infrared absorption cross sections near 3.3 $\mu$m have been obtained for ethane, C$_{2}$H$_{6}$. These were acquired at elevated temperatures (up to 773 K) using a Fourier transform infrared spectrometer and tube furnace with a resolution of 0.005 cm$^{-1}$. The integrated absorption was calibrated using composite infrared spectra taken from the Pacific Northwest National Laboratory (PNNL). These new measurements are the first high-resolution infrared C$_{2}$H$_{6}$ cross sections at elevated temperatures.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 Infrared absorption cross sections near 3.3 $\mu$m have been obtained for ethane, C$_{2}$H$_{6}$. contribution 0.53 0.92 0.11 asserted 1.00
s1 These were acquired at elevated temperatures (up to 773 K) using a Fourier transform infrared spectrometer and tube furnace with a resolution of 0.005 cm$^{-1}$. method 1.00 0.95 0.06 asserted 1.00
s2 The integrated absorption was calibrated using composite infrared spectra taken from the Pacific Northwest National Laboratory (PNNL). method 1.00 0.56 0.04 asserted 1.00
s3 These new measurements are the first high-resolution infrared C$_{2}$H$_{6}$ cross sections at elevated temperatures. contribution 0.80 0.88 0.77 asserted 1.00

What kind of paper the classifier reports this is: empirical study 0.97 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

Infrared absorption cross sections near 3.3 $\mu$m have been obtained for ethane, C$_{2}$H$_{6}$. These were acquired at elevated temperatures (up to 773 K) using a Fourier transform infrared spectrometer and tube furnace with a resolution of 0.005 cm$^{-1}$. The integrated absorption was calibrated using composite infrared spectra taken from the Pacific Northwest National Laboratory (PNNL). These new measurements are the first high-resolution infrared C$_{2}$H$_{6}$ cross sections at elevated temperatures.

Human review
How the literature uses it

What this paper does with the arXiv papers it cites

Each citing sentence is taken from the citing paper's LaTeX source and typed by Pith's classifier. A label appears at probability 0.8 or more (0.95 for support), a contest at 0.7 or more; the quoted words are the citing authors'. How each label was checked · JSON

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.